Die lte&

No, [0 W/G 50-9'!7 THE -TEXAS ^&M UNIVERSITY SYSTEM TEXAS TRANSPORTATION INSTITUTE -

COLLEGE STADON TEXAS 77843 TRAN8 PORT OPE *iADONS PROGRAM (713) 845-5817 May 3, 1981 Mitzie Solberg Emergency Preparedness Development Branch

.U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Dear Mrs. Solberg:

Attached is the summary of the review of the Grand Gulf evacuation time estimate. The review was made in accordance with NuREG 0654 Rev 1 even though the report was dated July 11, 1980.

The report is. deficient in documenting the data used, such as enumeration of the various population segments by sectors. The method-ology appears to be adequate, however the limited documentation makes it impossible to substantiate such a conclusion. Attached _is a summary of the ra' ting relative to the various items enumerated ir. NuREG 0654

~

Rev I, which also indicates the overall evaluation as being poor.

Sincerely, Thomas Urbanik,II Assistant Research Engineer TU/bb Enclosure i

8106M07 M TRANSPORTADON RESEARCH AND DEVELOPMENT

c EVALUATION OF EVACUATION TIME ESTIMATE Grana bulf Item Excel.

Adeq.

Poor None I.

Introduction A. Maps X

B. Assumptions X

C. Methodology II.

Demand Estimation A. Permanent Residents

8. Transient Populations C. Special Facility Population X

D. EPZ Sub-areas X

III. Traffic Capacity A. Evacuation Roadway Network X

-B. Roadway Segment Characteristics X

IV.

Analysis A. Report Format X

B. Methodology' V.

Other Requirements X

, VI.

Overall X

  • Note: Rating predicated on poor documentation.

Revised 5:1 83