ML19350E956
| ML19350E956 | |
| Person / Time | |
|---|---|
| Site: | 07109111 |
| Issue date: | 06/05/1981 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19350E955 | List: |
| References | |
| NUDOCS 8106230693 | |
| Download: ML19350E956 (3) | |
Text
-
e Form NAC418 U.s. NUCLEAR REGULATORY CouutssioN 8
CERTIFICATE OF COMPLIANCE 10 c 71 For Radioactive Materials Packages 1.tal Certifecate 1.(b) Pevesion No.
1.
I a Id tefication No.
1.'.d ) ages No. 1.{e) Total No. Pages
- 2. PREAMis'LE
' 2.(a)
Thes certefecate 's issued,to set sty sections 173.393a.173.394,173.395, and 173.396 of the oeoartenent of Transoortation Hazarocus e
Msterials Regulations (49 CFR 170-189 and 14 CFR 1031 and Sections 146-19-los and 146-19-100 of the Ceoartment of Transportation oangerous Cargoes Regulations 146 CFR 146-149), as amended.
2.It 1 De packaging and contents described in item 5 below meets the safety standards set forth in suopert C of Title 10. Code of Federal Regulations. Part 71, Packagmg of Rad oactive Materials for Transoort and Transportation of Sad.oactive Metenel Unoer Certain Conditions.**
2.(c)
This certificato does not relieve the consegnor from compliance with any requirement of the regulations of the U.s. oeoartment of Transcortateon or other apolicsole regulatory agencies, including the government of any country through or into which the osckage wdl be transoorted.
- 3. This certificate is issued on the basis of a safety analys s report of the oackage design or appicatson-
- 3.fal Prepared oy (Name and address #
3.(b)
Titte and id.ntification of report or aoolication:
Nuclear Packaging, Incorporated Nuclear Packaging, Inc., application dated 815 South 28th Street March 6, 1978, as supplemented.
Tacoma, WA 98409 3.cci cocket No.
71-9111 4 CONOlTIONS This certificate is conditional upon the fulfilling of the rooverements of Sucomet o of 10 CFR 71. as aoolicacie, and the conditions soecified in item 5 beeow.
- 5. osectiotion of Packaging ond Authorsted Contents. Mocol Number, Fissile Class. Otner Conditions. nd ReferenasI (a) Packaging (1, Model No.:
CN56-80-2 l
(2) Description A steel encased, lead shielded cask for solid radioactive material meeting the rsquirements for low specific activity racioactive material.
The overall dimensions of the cask are 70-1/2-inch diameter by 78-5/8-inch height. The cask consists of two concentric carbon steel cylindrical shells surrounding a 4-1/4-inch thick lead shield.
The 3/8-inch thick inner shell has a 59-inch I.D., and the 1-inch thick outer shell has a 70-1/2-inch 0.0.; the base consists of 4-inch thick welded steel plates of 60-inch diameter and 70-1/2-inch diameter, and a stepped welded lid comprised of two A-inch thick steel plates containing a centered 29-inch diameter secondary lid of similar construction with an additional 1-inch thick upper plate.
The containment cavity is 59-inch diameter by 58-inches high.
Closure of the primary lid is accomplished. by eight,1-1/4-inch bolts or studs and nuts.
Both lids are sealed using silicone gaskets l
bonded to the lid plates.
The secondary lid has a redundant neoprene seal.
A plugged drain port is located at the cask bottom.
The cask is lined with 12 gauge stainless steel.
Three li~f t lugs, located on the sec::ndary lid are used for lifting both the cask and the primary lid.
Four lugs, welded to the outer shell are used for tie-down.
The package gross weight is approximately 51,500 pounds.
e 8106230/83
y
~
]
i
.Page 2-- Certificate No.-9111 - Revision No. 5
. Docket No.' 71-9111 S.
(a)
(3) ' Drawing The packaging is fabricated in accordance with Nuclear Packaging, Incorporated Drawing No. BC-20-2000, Sheets 1 and 2 of 2, Revision G.
(-
(b) Contents (1) Type and form of material (1) Greater than Type A quantities of byproduct material contained in solids and solidified waste, meeting the requirements for-low specific activity radioactive materials as defined in 10 CFR $71.4(g), in secondary containers.
(ii) Greater than Type A quantities of bypmduct material contained in activated solid compunents meeting the requirements for low special activity radioactive material as defined in 10 CFR 571.4(g).
(2) ' Maximum quantity of material per package Greater than Type A quantities of radioactive material with the weight of the contents, secondary containers and shoring not exceeding 7,500 pounds.
The decay heat load shall not exceed 400 watts.
G.
Shoring shall be provided in the shipping cask cavity sufficient to prevent signifi-cant movement of the contents or secondary containers relative to the outer packaging under normal conditions of transport.
7.
The drain line shauld be plugged and sealed prior to transport.
8.
The package authorized by this certificate shall be transported on a motor vehicle, railroad car, aircraft, inland water craft, or hold or deck of a seagoing vessel assigned for sole use of the licensee.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
10.
Expiration dated:
July 31, 1983.
ed
j J
a.. -
\\
- Page 3~- Certificate No. 9111 - Revision No. 5 - Docket No. 71-9111
~ REFERENCES I
Nuclear Packaging, Incorporated application dated March 6,1978.
Supplements dated: June 7 and 28, 1978; and December 17, 1980.
Chem-Nuclear Systems, Inc. Supplement dated June 29, 1979.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION-e:
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety-Date:
.,,e n r 1981 6
~
~..~e--v~