Responds to IE Bulletin 80-23, Failures of Solenoid Valves Mfg by Valcor Engineering Corp. No Valcor Valves W/Cited Part Numbers Are in Use
ML19350B664
Person / Time
Site: River Bend  
Issue date: 01/23/1981
From: Draper E
GULF STATES UTILITIES CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-80-23, RBG-9551, NUDOCS 8103230223
Download: ML19350B664 (1)


Text

b GULF STATES UTILITIES COMPANY

  • OS* OFFICE 80x 235'.

BEAuvCN*

  • E 's As704 AAEA CODE 713 838 3943 January 23, 1981 y'10 RBG - 9551 File Code Nos. G9.5, G9.33.1 N I%

/

Mr. Karl V. Seyfrit, Director b

Region IV Office of Inspection & Enforcement h[Y U.S. Nuclear Regulatory Commission 3

Tr A /

L ~, -

]By b(

N 4-611 Ryan Plaza Drive, Suite 1000

?

Arlington, Texas 76011 ky 5

Dear Mr. Seyfrit:

y

's g

River Bend Station - Units 1 & 2 Refer to:

RIV Docket No. 50-458/Bu11etin 80-23 50-459/ Bulletin 80-23 Gulf States Utilities (GSU) has conducted a review of the

~

River Bend Station specified equipment with regard to I&E Bulletin No. 80-23.

The River Bend Station design does not specify Valcor solenoid valves having part numbers (P/N's) V70900-21-1 and V70900-21-3. This concludes our response to this Bulletin.

Sincerely, g

E. Linn Draper, o Vice President Nuclear Technology ELD /RJK/ mea cc: NRC Office of Inspection & Enforcement Division of Reactor Operations Inspection Washington, D.C.

20555

'B'1 0 3 9 3 0 % b B

.-