ML19350B309

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 81-06, Failure of Ite Model K-600 Circuit Breaker. No Response Required
ML19350B309
Person / Time
Site: Atlantic Nuclear Power Plant 
Issue date: 03/11/1981
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Collier A
OFFSHORE POWER SYSTEMS (SUBS. OF WESTINGHOUSE ELECTRI
References
NUDOCS 8103200246
Download: ML19350B309 (1)


Text

-

e4 g* 8Cw,(o, UNITED STATES g

f NUCLEAR REGULATORY COMMISSION yj,

'\\.)"ujf ' gI REGION 11

,; [ '

101 MARIETTA ST., N.W., SulTE 3100 o

ATLANTA, G EORGIA 30003 o

MAR 111981 In Reply Refer To:

RII:JP0 (f0-43 D Offshore Power Systems ATTN:

A. R. Collier, President P. 0.. Box 8000 Jacksonville, FL 32211 Gentlemen:

The enclosed IE Information Notice No. 81-06 contains information that may be ap?11 cable to your facility regarding the failure of an ITE Model K-600 cir-cuit breaker.

No specific action or response is requested at this time; however, pending the results of NRC staff evaluations of this matter, further licensee actions may be requested.

Should you have any questions regarding this information notice, please contact this office.

Sincerely, Jt, James P. O'Reilly Director

Enclosures:

1.

IE Information' Notice No. 81-06 2.

List.of Recently Issued IE Information Notices t

w..si m

g-

?3 n

oti=

a.u.

e-g r,:

"".-'?<*,4 7 = E :] -

y(qg 1

g n

r

-p b,

OW

c e

SSINS No.:

6835 Accession No.:

8011040269 LG 8;-06 D

' 'f3 o UNITED STATES w

QU I

NUCLEAR REGULATORY COMMISSION 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 March 11, 1981 IE Information Notice No. 81-06:

FAILURE OF ITE MODEL K-600 CIRCUIT BREAKER

Purpose:

.Th'a purpose 'of. thi s : info'rmation notic'e is to provide early. notification of a matter that could adversely affect the safety of nuclear power plants.

Toward this end, this information notice alerts holders of operating licenses and construction permits of a possibly generic deficiency involving Model K-600 circuit breakers manufactured by ITE.

Description of Circumstance:

By letter dated February 20, 1981, the Sacramento Municipal Utility District informed us that, while performing preventive maintenance on electrical circuit breakers at its Rancho Seco facility, an ITE Model K-600 breaker was observed not to trip. An investigation revealed that a tripping coil wire had slipped out of its terminal.

Further examinations revealed that the coil wire si:e was AWG 20, whereas the mating lug was sized for AWG 16-14 wire. A check of other ITE electrical breakers indicated that the problem may be generic.

Subsequent to the letter, the Sacramento Municipal Utility District informeo us orally that ITE Model K-1600 breakers have the same deficiency and that Model K-3000 breakers may be similarly affected.

The_information provided by the Sacramento Municipal. Utility District is pre-

~

liminary and'will'be^followed'by a complate report.

Consequently, we have'not yet evaluated the safety significance of this event..Nevertheless, the information herein is being provided as an early notification of a possibly significant event. Although no specific action or response is requested at this time, recipients should review'the information for possible applicability to their facilities.

If NRC evaluations so indicate, further licensee actions may be requested.

If you have any questions regarding the information contained herein, please contact the Director.of the appropriate NRC Regional Office.

~

Attachment:

Recently issued IE Information Notices

Attachment IN 81-06 March 11, 1981 RECENTLY ISSUED IE INFORMATION NOTICES Information Date of Notice No.

Subject Issue Issued to 81-05 Degraded DC System at 2/10/81 All power eactor Palisades facil.ities with an OL or CP 81-04 Cracking in Main Steam 2/27/81 All power reactor Lines facilities with an OL-81-03 Checklist for Licensees 2/12/81 All power reactor Making Notifications of facilities with an Significant Events in OL Accordance with 10 CFR 50.72 81-02 Transportation of 1/23/81 All Radiography Radiography Devices licensees 81-01 Possible Failures of 1/16/81 All power reactor General Electric Type facilities with an HFA Relays OL or CP.

'80-45 Pctential Failure of 12/17/80 All PWR facilities BWR Backup Manual Scram with an OL or CP Capability 80-44.

Actuation of.ECCS in-the 12/16/80-All PWR facilities Recirculation Mode While'

'with an OL or CP in Hot Shutdown 80-43 Failures of the Continuous 12/5/80 ^

All power reactor Water Level Monitor for facilities with an the Scram Discharge Volume OL or CP at Dresden Unit No. 2 80-42 Effect of Radiation on 11/24/80 All power reactor Hydraulic Snubber Fluid facilities with an OL or CP 80-41 Failure of Swing _ Check 11/10/80 All power reactor Valve in the Decay Heat facilities with an Removal ~ System at Davis-0L or CP Besse Unit No. 1 OL = Operating Licenses CP = Construction Permits