c 4 a 7 % ft.- A
- l C CONNECTICUT YAN KEE ATOMIC POWER COMPANY BERLIN. CO N N ECTIC U T P. o. som ato HARTFORD. CONNECTICUT 06109 j
l
'7' 203. 7.1n CYH-77-349 December 22, 1977 U. S. Nuclear Regulatory Commission Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406 Attn: Mr.Boycedrier Director RE:
B. H. Grier letter to D. C. Switzer dated November 4, 1977 I. E. Bulletin No. 77-04
Dear Mr. Grier:
This letter is in response to your request regarding the action to be taken at Connecticut Yankee Atomic Power Company, Haddam Neck Plant referencing 1. E. Bulletin No. 17-04, "pH control of Containment Sump Water following a LOCA."
Presently Connecticut Yankee Atomic Power Company neither utilizes nor plans to utilize a system for pH control of containment sump water following a LOCA.
Very truly yours, CONNECTICUT YANKEE ATOMIC POWER COMPANY D. C. Switzer President DCS:HHW/kwc Ab) cc: Office of Inspection and Enforcement i
Division of Reactor Operations Inspection Washington, DC 20555
~