PHILADELPHIA ELECTRIC COMPANY 2301 M ARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 1881 1981 (2151 841 4o0o May 14, 1981 RE: Docket No. 50-277 rm.K

/y, g --

,s

.[ y',

7.:,

ty

  • h. l '

l.

" ' " ~ ~ ' ^

John F. Stolz, Chief i%

'C

'/j,l ~. S '.$ 3 5 ^

Operating Reactors Branch #4

~

,., m e:a Division of Licensing ut U.S. Nuclear Regulatory Conmission Washington, D. C. 20555 l

f

Dear Mr. Stolz:

l l

This letter is to follow-up on recent telephone conversations between your staff (M. Fairtile and J. Volglewede) and L. F.

Rubino of Philadelphia Electric concerning our September 30, 1980 license amendment request submitted for Peach Bottom Unit 2 to expand the maximum average planar linear heat generation rate (MAPLHGR) limits over an increased exposure range.

l Your staff advised that because of NRC fission gas release concernsathighexposure,theMAPLHGRlimitat40,000 MWD / twill be reduced from 9.3 kw/ft as we submitted on September 30 to 8.4 kw/ft for Unit 2 8D274L and 80274H fuel types. We are in agreement with this reduction and have attached revised Technical Specification Figures 3 5.1.C and 3.5.1.0.

I In addition, we understand that the staff is currently reviewing additional information provided by General Electric Company which adm esses the fission gas release concern and that t

8145190290

J i

John F. Stolz, Chief May 14,1981 Page 2 RE: Docket No. 50-277 i

if this matter is satisfactorily resolved, the above MAPLHGR reduction will no longer be required and our original as submitted MAPLHGR limits will be applicable.

If you require any additionel information, please do not hesitate to contact us.

Very truly yours, A

[MO' M. J.

ney Super tendent Gener tion Division / Nuclear LFR:cas i