05000313/LER-1981-006, Forwards LER 81-006/03L-0

From kanterella
(Redirected from ML19347F086)
Jump to navigation Jump to search
Forwards LER 81-006/03L-0
ML19347F086
Person / Time
Site: Arkansas Nuclear 
Issue date: 05/05/1981
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Madsen G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19347F087 List:
References
1R-0581-02, 1R-581-2, NUDOCS 8105150231
Download: ML19347F086 (1)


LER-1981-006, Forwards LER 81-006/03L-0
Event date:
Report date:
3131981006R00 - NRC Website

text

  • y ARKANSAS POWEA & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK. ARKANSAS 72203 (501)371-4000 May 5, 1981 cf[ Y.b t

8 1R-0581-02 9

%jl/Sg7A8 9u Mr. G. L. Madsen, Chief S

N

~

Reactors Projects Branch U. S. Nuclear Regulatory Com.

y Region IV 611 Ryan Plaza Drive, Suite 1000 y qi Arlington, Texas 76011 SUBJECT: Arkansas Nuclear One - Unit 1 Docket No. 50-313 License No. DPR-51 Licensee Event Report No. 81-006/03L-0 (File: 0520)

Gentlemen:

In accordance with Arkansas Nuclear One - Unit 1 Technical Specification 6.12.3.2.b, attached is the subject report concerning the failure of an Emergency Feedwater system valve operator control power fuse.

Very truly yours, I

.a.

e

[ Manager, Licensing David C. Trimble R, t>

DCT:GAC:1p Attachment cc: Mr. Victor Stello, Jr., Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Comm.

Washington, D.C.

20555 Mr. Norman M. Haller, Director Office of Management and Program Analysis U. S. Nuclear Regulatory Com.

Washington, D.C.

20555 81051 so,nt S

MEMBEA MtOOLE SOUTH UTILITIES SYSTEM i