ML19347E303

From kanterella
Jump to navigation Jump to search
Forwards LER 81-001/03L-1.Detailed Event Analysis Encl
Date released: 12/27/2019 Download: ML19347E303


LER 81-001/03L-1:on 810117,two Leaks Found in 1-inch Bypass Around MU-V17 During Limited Plant Heatup.Caused by Flange Socket Fillet Weld Failure Due to fabrication-induced Crack in Root of Weld
ML19347E307
Person / Time
Site: Crane 
Issue date: 04/20/1981
From: Mitchell D
METROPOLITAN EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19347E307 (1)
Forwards LER 81-001/03L-1.Detailed Event Analysis Encl
ML19347E302
Person / Time
Site: Crane 
Issue date: 04/20/1981
From: Hukill H
METROPOLITAN EDISON CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19347E302 (2)