g Thomas J. Martin Public Service Electric and Gas Co... par / 80 Park Plaza Newark, N.J. 07101 201/4304316 Vics President Engineering and Construction March 12, 1981 Mr. Boyce H. Grier, Director Office of Inspection and Enforcement U.
S. Nuclear Regulatory Commission Region 1
[g I
631 Park Avenue King of Prussia, Pennsylvania 19406
/ 27 jh1 Apgb /S67g 6~
u 73 ha, Dear Mr. Grier-Y NRC BULLETIN NO. 79-28 r
POSSIBLE MALFUNCTION OF NAMCO MODEL EA180 7
LIMIT SWITCHES AT ELEVATED TEMPERATURES Y/
f NO. 1 AND 2 UNITS HOPE CREEK GENERATING STATION We replied to IE Bulletin No. 79-28, dated December 7,
- 1979, on February 6, 1980 and we now have additional information to report.
The bulletin warns of a potential malfunction of NAMCO Model EA180 limit switches at elevated temperatures.
The problem is caused by a defective top cover gasket and affects all i
NAMCO Model EA180 switches date coded between February 1979 and August 1979.
l l
It has been determined that four suppliers for the Hope Creek l
Site have supplied or plan to supply the subject switches.
l Detail information pertinent to each procurement is noted below:
I 1.
Purchase Order J605(Q) - The NAMCO limit switches supplied l
by Fisher were not frcm the defective batch.
2.
Purchase Order J601(Q) - Masonellan replaced the gaskets coded between February and August 1979.
The switches have been marked with yellow paint on the switch housing next to the date code in question.
8104240337
i t
Boyce H.
Grier 3/12/81 3.
Purchase Orders P301(Q) and P302(Q) - Anchor / Darling shipped to Hope Creek valves having NAMCO EA180 switches.
A field check was made and the defective gaskets were replaced.
Valves still to be shipped will have the pro-per gaskets.
4.
Purchase Order P303A(Q) - Rockwell will supply switches with proper gaskets.
Should any. additional information be desired, we will be pleased to further discuss it with you.
Very truly yours, I
CC Office of Inspection and Enforcement Division of Reactor Construction Inspection Washington, DC 4
i 8
i
.-,...,-...~,3
,,,r.yr.--.-
a,,w..,
,e
,r,.-.,_,-w.--,
s
.r.-
,,.,,.. -, _.