T/G.

f ['p ua UNITED STATES j'"I

  • g p' n NUCLEAR REGULATORY COMMISSION

/.. j REGION 11 101 MARIETTA sT., N.W., SUtTE 3100

,8 ATI.ANTA, G EoRGIA 30303 0

FEB 2 01981 l

In Reply Refer To RII:RLW 6 3cg 7 @,'

6 1/80-12?

Babcock and Wilcox Company 2[ ff ATIN: Mr. W. F. Heer, Manager 9-' c,4 Pg78 g

Virginia Operations, Nuclear Materials 8/

Commercial Nuclear Fuel Plant h.

4 and Manufact.uring Division

/

P. O. Box 800 b

/s 4

Lynchburg, VA 24505 Gentlemen:

This refers to the inspection conducted by R. L. Woodruff and W. J. Millsap of this office on November 12, 1980, of activities authorized by NRC License No.

SNM-1168 for the Lynchburg facility, and to the discussion of our findings held with you at the conclusion of the inspection.

A.eas examined during the inspection and our findings are discussed in the enclosed inspection report.

Within these areas, the inspection consisted of j

selective exar.inations of procedures and representative records, interviews with l

personnel, and observations by the inspectors.

Within the scope of this inspection, no items of noncompliance were. disclosed.

The consultant representatives identified recommendations for improvement of your monitoring program. These items will be referred to our Office of Nuclear haterial j

Safety and Safeguards for consideution.

In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this office to withhold such information fram public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so l

that proprietary information identified in the application is contained in a separate part of the document. If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

Should you have any questions concerning this letter, we will be glad to discuss them with you.

1 SincereJy, J. P. Stohr, Chief Fuel Facility and Material Safety Branch j

l

Enclosure:

Inspection Repor No.

70-1201/80-12 810326 0 k%

- -