Research Reactor Facility UNIVERSITY OF MISSOURI Pesearch Park Columoia. %ssoun 65211 March 3,1981 reiemne at4) 682-4211 Mr. James R. Miller Standardization and Special Projects Branch Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention: Mr. Robert Carter

Reference:

(a) Docket 50-186 'g p < ,1 University of Missouri .v s Q ' ,/

ge[#

Research Reactor CP r -

(b) Letter to Standardization C aD and Special Projects Branch from University of Missouri dated December 15, 1980.

\(5^

'f A.

p >

j

/ '/" ' 'j

Subject:

Change to Technical Specification l .20 Raactor Secured.

j

Dear Sir:

l We are requesting to make a ;;ight change to our Technical Specification revision submitted December 15, 1983. In talking with Mr. Carter, we realized our statement concerning control rod work could be misinterpreted. Therefore, Technical Specification 1.20(d) should be:

No work is in progress involving the control rods or control rod drives with the exception of installing or removing dummy load control rod test connectors.

Additionally, section 1.20.b(2) is revised to be:

(2) A licensed operator is present in the Control Room and the dummy load control rod test connectors are installed.

The request for having the control rod magnet current switch (1514) in the "off" position is being removed. In consideration of the potential for inadver-tently switching the position of 1514 during a maintenance day, we have removed it from the technical specification request.

W+ O I o

E(CepiB >' 3 4

COLUMBIA KANSAS CITY ROLLA ST. LOUIS 4/j\jgJ h an equal opportun>ry institution 8103100fA ' /

Mr. Janas R. Miller March 1, 1981 Page 2 A copy of the currently requested technical specification has been attached, if there are any questions please call me (314) 882-4011.

Sincerely. -,

g)m,gs, }./ , ff',/ .

~

l J. C. McKibben Reactor Manager JCMK:vs Attachment