ML19347C953

From kanterella
Jump to navigation Jump to search
Forwards LER 81-004/01T-0
Date released: 12/27/2019 Download: ML19347C953


LER 81-004/01T-0:on 810220,four Low Condenser Vacuum Switches Tripped in Excess of Tech Specs During Test.Caused by Setpoint Drift.Switches Recalibr
ML19347C956
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 03/02/1981
From: Kopacz J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19347C956 (2)
Forwards LER 81-004/01T-0
ML19347C952
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 03/02/1981
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19347C952 (1)