ML19347C903

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Reactor Protection Sys Panel Design Deficiencies Initially Reported on 800807.Util Is Awaiting Info from GE Re Final Corrective Actions
ML19347C903
Person / Time
Site: Hartsville, Phipps Bend  Tennessee Valley Authority icon.png
Issue date: 02/12/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-81-365-000 10CFR-050.55E, 10CFR-50.55E, NCR-PRC-80-31, PT21-81-365, PT21-81-365-000, NUDOCS 8103100281
Download: ML19347C903 (2)


Text

o,m ;, m.,.e < i..,,,

m

. ;...a.

,u,_#

.~,.m

%lwn-

~

PART 21 IIEfflFICAfl0N NO.

ta-sta-coo _

_ COT /M IKENeakgGua'm'g DATE OF lHIER. Thbt

_ DOCKET NO fco-Grol 6m)Eml621V:c-6%l691 '

DATE DISTRIBUIED zim381 n.m.

ORIGlmL REPORT1 SUPPLFfENTARY T

DISTRIBUTION:

REACTOR (R) i FUEL CYCLE &

SAFEGUARDS (S)

MTERIALS (I'D s

gg r rig i IEFILES EES IE FILES AD/SG AD/FHEl AD/ROI REGIONS I,II,III,IV,V REGID'tS I,II,III,IV,V REGICNS I,II,III,IV,V VENDOR BR. R-IV VENDOR BR. R-IV VENDOR BR. R-IV LDEB / ffA FNB 5715 sSS/FCFE SS-395 NPNDOL AE00 FNB 7602 LDEB/f?A f,13 5715 ffES / SG SS-881 NRP/ DOE AEOD FNB7602 LDEB/FPA FIG 5715 NRR/DSI ASLBP FM 450 AE0D FI6 7602 NMT SAP /SP fiE-7210A ASl3P E/W 450 NRP/ DOL 016 ENTPAL FILES 016 CENTPAL FILES ASLBP FM 450 N FILES ( W RON)

CENTPAL FILES (GROTO CElffRAL FILES 016 PDR CENTPAL FILES SS-395 CENTRAL FILES (GR0fD LPDR PDR

]Rpg PDR TERA TERA, p LPDR ll %%gf,W//;*

t 5

CTION:

c, PRELIMINARY EVALUATION OF THE ATTACHED REPORT ItOICATES FOR FOLLOMJP AS SHO'd BELOW:

IE [

NRR[

IEES [

OTHER [

EES S

81031oo761 REV. 8/1/80 sinho t

idtlto

~

T\\GL Qcak ~zt "L.hc %\\- 5th-cco TENNESSEE VALLEY AUTHORITY C.

CH ATTANOOGA. TENNESSEE 374ot Qg Q5, 400 Chestnut Street Tower II b-653}564 February 12, 1981 Mr. James P. O'Reilly, Director Office of Inspection and Enforcement

'U.S. Nuclear Regulatory Commission Region II - Suite 3100 101 Marietta Street

' Atlanta, Georgia 30303 s.

Dear Mr. O'Reilly:

HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - REPORTABLE DEFICIENCY -

RPS PANEL DESIGN DEFICIENCIES, (NCR PRC 80-31)

Initial report of the subject deficiency was cade to NRC-OIE, Region II. Inspector, F. S. Cantrell, on August 7, 1980.

The first and i

second interim reports on the subject deficiency were transmitted on L

September 3 and Nove=ber 18, 1980, respectively.

In compliance

' with paragraph 50.55(e) of 10 CFR Part 50, this constitutes the

-third interim report for the subject deficiency.

TVA has roade no progress on this problem other than that previously reported. "We are awaiting information from CE regarding final corrective actions. We anticipate transmitting the final report on

' or before April 30, 1981.

TVA considers 10 CFR Eg;1,2J applicable to this reportable deficiency.

If you have any questions concerning this subject, please call Jim Domer at FTS 857-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY M

L. M. Mills,' Manager Nuclear Regulation and Safety f

cc:

Mr. Victor Stello, Director j-U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Washington, DC. 20555-i

~

An Ecual 0;;ortunity Emptcyer