ABNORMAL OCCURRENCE REPORT Big Rock Point Plant 1.

Report No: A0-29-75, Docket 50-155 2a.

Report Date: December 16, 1975 2b.

Occurrence Date: December 6, 1975, Classified as A0 on December 9, 1975 3

Facility: Big Rock Point Plant, Charlevoix, Michigan h.

Identification of Occurrence: Failure of piping component in control rod drive pump No 1 discharge piping.

5 Conditions During Occurrence: Plant shut down for minor repairs and rou-tine testing.

6.

Description of Occurrence: A through wall water leak was observed in a threaded 1" Schedule 160 pipe nipple at the inlet to the pump discharge relief valve on the No 1 system. The unit was immediately removed from service and the No 2 pump was immediately put in service. Maintenance was notified to investigate and repair.

7 Designation of Apparent Cause of Occurrence: Unknown. Probable cause is vibration induced fatigue. A metallurgical examination will be conducted.

8.

Analysis of Occurrence: The pump system provides drive cooling water, scram accumulator charging energy and normal drive maneuvering powe" and these functions were not lost due to this deficiency.

9 Corrective Action: The pipe nipple and associated flange were replaced and satisfactorily tested prior to plant start-up on December 7, 1975 10.

Failure Data: One-inch carbon steel Schedule 160 pipe nipple.