Forwards Interim Preliminary Draft Rept Review of Recent Malfunctions of BWR Scram Sys
ML19347C329
Person / Time
Site: Millstone, Hatch, Dresden, Peach Bottom, Browns Ferry, Brunswick, Duane Arnold  
Issue date: 08/08/1980
From: Stampelos J, Gary Young, Zukor D
Advisory Committee on Reactor Safeguards
To: Plesset M
Advisory Committee on Reactor Safeguards
Shared Package
ML19347C330 List:
References
TASK-04-02, TASK-4-2, TASK-RR ACRS-SM-0185, ACRS-SM-185, NUDOCS 8010170319
Download: ML19347C329 (1)


Text

(AKfG

,(

'o, UNITED STATES NUCLEAR REGULATORY COMMISSION n

{

ADVISORY COMMITTEE ON REACTOR SAFEGUARDS 4

WASHINGTON, D. C. 20555

%4....$

MEMORANDUM FOR:

Dr. Milton S. Plesset, Chairman Subcommittee on Fluid Dynamics FROM:

Members of ACRS Task Force

SUBJECT:

A REVIEW 0F RECENT MALFUNCTIONS OF BWR SCRAM SYSTEM The Task Force has prepared the attached draft report. We look forward to discussing the report with the Subcommittee during the August 19-20 meeting.

/-~ n / -

r 1:(~. d{dp02 John Stampelos, CWap.1, and 6 Sec. 3.4 GIVA

. NC'M Garry Youhg, Chap. 2 d4 Sec. 3.2 3.5 shW M!cBt)

Dorothy Zu{or, g)ap. 5 Tec. 3.3 80101703fy