ML19345H401

From kanterella
Jump to navigation Jump to search
Forwards LER 81-035/03L-0
Date released: 12/25/2019 Download: ML19345H401


LER 81-035/03L-0:on 810415,all Three Chlorine Detectors Failed to Meet Min Electrolyte Drip Rate Criteria Specified in Surveillance Test.Caused by Flow of Electrolyte Being Blocked.Wicks Replaced & Glass Orifices Cleaned
ML19345H403
Person / Time
Site: Beaver Valley
Issue date: 05/14/1981
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19345H403 (2)
Forwards LER 81-035/03L-0
ML19345H400
Person / Time
Site: Beaver Valley
Issue date: 05/14/1981
From: Werling J
DUQUESNE LIGHT CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19345H400 (2)