Text
!
O I
l p UNITED NUCLEAR g
C O R P o R A T I o N P.O. BOX 1883 l
March 31,1965
- =~c a;;,a al,;=,
777 5381 Director of Regulations U. S. Atomic Energy Commission Washington 25, D. C.
Attention:
Mr. Harold L. Price
SUBJECT:
Supplemental Report of the Accidental Criticality of Wood River Junction, Rhode Island, July 1964
Reference:
United Nuclear Corporation Report Dated August 21,1964 Gentlemen:
My transmittal letter to the referenced report which was UNC's first report of the July 24,1964 incident mentioned that at a later date UNC planned to submit a supplemental report. The supplemental report was to concentrote on the nuclear physics investigation which we hoped would be of some interest to the nuclear community.
The ottoched report has now been completed and includes a significant amount of original work. Copies of this report are being sent to all recipients of the origi-nol report and we trust the contents will be of general interest.
Appreciation is again expressed to the Atomic Energy Commission personnel who have consulted and assisted in several phases of this work.
Very truly yours, J. A. Lindbe g l
Vice President JAt/b l
1 l
'(
/
810501
.