O Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages OnQC g

(f ca /onog /a 1

g

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394.173.395 rnd 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the copertment of Transportation aangerous Cargoes Regulations (46 CFH 146-149), as amended.

2.40)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title to. Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Tr.nsport and Transportation of Radioactive Material Under Certam Conditions!'

2.tc)

This cc-tificate does not relieve the consignor from compliance with any requirement of the regulations of the U.s. cepartment of Transportation or otner apolicaole regulatory agenaes. including the government of any country througn or into which the package will be transoorted.

3. This certificate is issued on the casas of a safety analysis report of the package assegn or application-3.ta)

Prepared by (Name and addressp 3.(b)

Title and identification of repor* oc acotication:

Hittman Nuclear & Development Hittman Nuclear & Development Corporation application Ccrocration dated January 13, 1977, as supplemented 9190 Red Branch Road Columbia, Maryland 21045 71-9086 3.ic) oose, No.

4 CONoiTIONS Tnis certificate is cenditional upon t~e fulfilling of tme reautrements of Subpart O of 10 CF A 71 as applicacie, and tPe conditions specified in itern S below.

5 Oeseriet.on of pacmaging and Authorizac Contents Modet Numeer, Fissile Ctass, Other Conditions, and

References:

(a) Packaging (1) Model No.:

HN-100 Series 1 (2) Description A steel encased, lead shicided cask for low specific activity material.

The cask is a right circular cylinder 81.5 inches high by 82.75 inches in diameter.

The cask cavity is 73.5 inches high by 75.5 inches in diameter.

The cask side wall consists of a 3/8-inch thick inner steel shell, a 1-3/4-inch lead shell, and a 7/8-inch thick outer steel shell.

The base is a 4-inch thick steel plate which is welded to the inner and outer steel shells of.the side wall.

A steel flange is welded to the inner and l

outer steel shells of the side wall at the top.

The lid is a 4-inch thick steel plate which is stepped to mate with the steel flange. The cask closure is sealed by a Viton 0-ring gasket located between the lid and steel flange.

Positive lid cl.osure is accomplished by thirty, 1-inch bolts. The lid contains a centrally located 4-in.ch stepped steel shield plug.

The shield pidg is sealed by a Viton 0-ring gasket, and sixteen, 1/2-inch bolts are used to provide positive closure.

Tie-down is accomplished by four tie-down lugs welded to the cask body.

There are three casks lifting lugs, three lid lifting lugs, and one shield plug lifting lug.

The package gross weight is 50,000 pounds.

i 8104220 #

l l

Page 2 - Certificate No. 9086 - Revision No. 6 - Docket No. 71-9086 (a) Packaging (continued)

(3) Drawings The packaging is constructed in accordance with Hittman Nuclear

& Development Corporation Drawing Nos. C001-5-9125, Revision 1; C001-5-9126, Revision 1; and C001-5-9127, Revision 0.

(b) Contents (1) Type and form of material Process solids either dewatered, solid or solidified meeting the require-ments for low specific activity radioactive material, in secondary containers.

(2) Maximum quantity of material per package Greater than Type A quantities of radicactive material with tne weight of the contents, secondary containers and shoring not exceeding 14,500 pounds.

6.

Shoring shall be placed between secondary containers and the cask cavity to minimize movement during normal conditions of transport.

The lid and snield plug lif ting lugs shall not be used for lifting the cask, and 7.

shall be covered in transit.

8.

Prior to each shipment, the packaging lid seals shall be inspected. The seals shall be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.

9.

The package authorized by this certificate shall be transported on a motor vehicle, railroad car, aircraft, inland watercraft, or hold or deck of a seagoing vessel assigned for the sole use of the licensee.

10.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

11.

Expiration date:

August 31, 1982.

REFERENCES Hittman Nuclear & Development Corporation application dated January 13, 1977.

Supplements dated: October 5, 1977; September 11, 1978; March 17, 1980; andMarch9,1981.l FOR THE U.S. NUCLEAR REGULATORY COMMISSION '

b Charles E.

acDonala, Ciiiel Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

. -.