ML19345G487

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Full Penetration Attachment Welds to Pipe in Class 1,2 & 3 Piping Sys.Programmatic Coverage Exists for Full Penetration Welds in Pipe Attachments & Electrical Supports
ML19345G487
Person / Time
Site: Summer 
Issue date: 04/03/1981
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8104070365
Download: ML19345G487 (2)


Text

_

A-SOUTH CAROUNA ELECTRIC a gas COMPANY post arrier som re+

CotunstA, SoWIM tARJUNA 228 i -

e j,

1.C. Nicr ots,Ja.

f('

~

v.c.e.ui......o

.c....

April 3, 1981 4.',--.

j

<j

... o f-

,J j

c.

N,s.;nN

.s s ', '

lC {.,.,. ;" J.? l $

[,G

_p 'jh8

,/

Mr. James P. O'Reilly, Director

(.-

/g U. S. Nuclear Regulatory Commission 9,

Region II, Suite 3100

/n, p.

/y 101 Marietta Street, N. W.

Subject:

Virgil C, Summer Nuclear Station Docket No. 50/395 Reportable Item in Accordance with 10CFR50.55(e) - Full Penetration Attachment Welds NRC Item 395/80-02-02

Dear Mr. O'Reilly:

This letter constitutes a supplement to our letter of March 17, 1981 on the subject reportable item as requested by Mr. Ed Girard in his recent inspection. The letter of March 17, 1981 discussed the cause and corrective action taken with regard to the item of full penetration attachments to pipe in Class 1, 2, and 3 piping systems.

This letter is to advise that in addition to the action noted above, we have reviewed our program for full penetration welds on ASME Code pipe supports and on electrical cable tray supports. Our Quality Control procedure FQCP 6.3.1 " Inspection of Fabrication and Installation of Pipe Hangers and Supports" was developed on March 14, 1980 prior to SCE&G's pipe support inspec-tion /re-inspection program to include and to document and inspection point of backgouged side of double beveled full penetration welds. Therefore, inspections were performed and documentation exists on site for full penetrations welds in-spected under this procedure. In the area of electrical supports, SCE&G Mechanical'0,C Instruction MF-6 was developed and implemented to assure the

. acceptability of full penetration butt weld connections. In addition, double beveled full penetration welds were re-examined and documented in accordance with the provisions contained in Instruction MF-6.

In the area of HVAC supports, an examination of the designs confirms that no full penetration welds were specified. Other type welds on HVAC support have been made and inspected to approved procedures.

s

/O 8104070 M

~

S

='

O Mr. James P. O'Reilly April 3, 1961 Page Two In summary, SCE&G believes that full programmatic coverage exists for full penetration welds in the areas of pipe attachments, pipe supports and electrical supports, and that the information contained herein supports previous items reported to the NRC dealing with welding in these areas.

Documentation is available on site for your review as desired. This is considered a final report on this subject and should provide you with sufficient information to resolve this matter.

Very truly yours, f f, T. C. Nichols, Jr.

HR:TCN:rh cc:

V. C. Summer G. H. Fischer T. C. Nichols, Jr.

C. A. Price D. A. "auman W. A. Williams, Jr.

R. B. Clary A. R. Koon A. A. Smith H. N. Cyrus J. B. Knotts, Jr.

J. L. Skolds

0. S. Bradham B. A. Bursey

-Document Management Branch I&E (Washington)

ISEG

' PRS NPCF File e

,y

- - -