ML19345E788

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-23, Failures of Solenoid Valves Mfg by Valcor Engineering Corp. Valves Not Used to Perform Any safety-related Functions at Facility
ML19345E788
Person / Time
Site: Pilgrim
Issue date: 12/29/1980
From: Morisi A
BOSTON EDISON CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
80-315, IEB-80-23, NUDOCS 8102060124
Download: ML19345E788 (1)


Text

.

k COLTON EIlDCIN COMPANY mamanAL crrecta 300 movLaToN ETmEET sostom. MAA5ACHussTTs 02199 A. V. M O RI 5 l MANAoER December 29, 1980 NUCLEAR OPERATIONS SUPPORT DEPARTMENT BECo Ltr. #80-315 g

[j,' '1,[ ~) N ev..

Mr. Boyce H. Grier, Director i~

Office of Inspection and Enforcement j~-

g),

Region I L'

U.S. Nuclear Regulatory Comission k"

JAN G Q 1981

  • M 631 Park Avenue A" u,w mom wwo" D King of Prussia, Pa.

19406

{\\.

fj awaiS5**

License No. DPR-35 Docket No. 50-293 Response to IE Bulletin #80-23

Dear Mr. Grier:

By letter dated November 14, 1980, you transmitted IE Bulletin No. 80-23,

" Failures of Solenoid Valves Manufactured by Valcor Engireering Corporation."

Boston Edison Company was requested to determine whether Valcor Solenoid Valves having P/N's V7u900-21-1 or -3 are used to perfonn any safety re-lated function at Pilgrim Nuclear Power Station.

Response

Valcor solenoid valves having P/N's V70900-21-1 or -3 are not used to perform any safety-related functions at Pilgrim Station.

Should you have any further questions or concerns on this subject, please do not hesitate to contact us.

Very truly yours, Oc7leita cc:

Di rector, Division of Resident and Regional Reactor Inspection Office of Inspection & Enforcement U.S. Nuclear Regulatory Comission Washington, D. C. 20555 JDK/gn B10 206 0.M n

~

s y-q r-