ML19345E264

From kanterella
Jump to navigation Jump to search
Forwards LERs 80-095/03L-0 & 80-096/03L-0
Date released: 12/25/2019 Download: ML19345E264


LER 80-096/03L-0:on 801121,control Problem W/Bypass & Main Feed Regulating Valves Caused Transient in RCS That Could Not Be Controlled within Limits.Caused by Improperly Tuned Control Mod for Feed Bypass Valves
ML19345E273
Person / Time
Site: Beaver Valley
Issue date: 12/15/1980
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19345E273 (2)
LER 80-095/03L-0:on 801121,during Safety Injection Accumulator 1A Level Channel 1 Test,Low Level Alarm Setpoint at Comparator LC-S1-920B Found One Gallon Below Tech Spec Min.Caused by Setpoint Drift.Comparators Recalibr
ML19345E269
Person / Time
Site: Beaver Valley
Issue date: 12/15/1980
From: Lacey W
DUQUESNE LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19345E269 (2)
Forwards LERs 80-095/03L-0 & 80-096/03L-0
ML19345E263
Person / Time
Site: Beaver Valley
Issue date: 12/15/1980
From: Werling J
DUQUESNE LIGHT CO.
To: GRIER B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19345E263 (2)