ML19345E020

From kanterella
Jump to navigation Jump to search
Forwards LER 80-083/03L-0
Date released: 12/25/2019 Download: ML19345E020


LER 80-083/03L-0:on 801116,feedwater Swing Caused Steam Generator 1-1 Level to Exceed Tech Spec Limits.Caused by Bad Relay in Integrated Control Sys.Relay 86/MBV-B Replaced. Relay 33X Changed on 801206
ML19345E021
Person / Time
Site: Davis Besse 
Issue date: 12/15/1980
From: Whitesell B
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19345E021 (2)
Forwards LER 80-083/03L-0
ML19345E018
Person / Time
Site: Davis Besse 
Issue date: 12/15/1980
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19345E018 (1)