Forwards Info Re Environ Qualification of safety-related Equipment Per 801001 Request
ML19345D731
Person / Time
Site: Crane Constellation icon.png
Issue date: 12/12/1980
From: Hukill H
METROPOLITAN EDISON CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
TLL-640, NUDOCS 8012160521
Download: ML19345D731 (2)


Text

.

Metropolitan Edison Cu npany Post Office Box 480 ll Middletown, Pennsylvanie 17057 717 9444041 Wrrter's Direct Dial Nurnber December 12, 1980 TLL 640 Office of Nuclear Reactor Regulation Attn:

D. G. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Enviroamen t. -- Qualification of Safety-Related Equipment Enclosed please find the information requested in your letter of October 1, 1980 relative to environmental qualification tests to be conducted on equipment to be used at TMI-l within the next two years.

Sincerely, l

l

\\

h D. b ill Director, TMI-l HDH:IF:LWH: bah Enclosure cc:

B. H. Grier H. Silver R. W. Reid l

I a-e E:

'i L

h

/)oo/

s i

l

//

l l

'/etropo tan Eason Company -s a Memoer of the Ge erai PuDuc U%t es Systern 8 G ] ~oIU

4

)'

TLL 640

].

EQUIPMENT ENVIRONMENTAL QUALIFICATION IEEE 323 1

EQUIPMENT TEST COGNIZANT ENGINEERING SYSTEM DESCRIPTION TYPE MODEL LOCATION SCllEDULF TESTS BY Fisher Expected Start

[

j E N Flow EF-V30A Actuator Valve Type CC 476

  • Marshall Town, April 1931 S. Deshmukh j

Control Assembly ~

Actuator Iowa i

Expected Start i

j Main Steam MS V6 Main Steam Fisher Type ED Fisher

  • Marshall Town, April 1981 S. Deshmukh

]

(MS)

Supply to EWP 657 Iowa L

Turbin Regulator Actuator Valve Expected Start Main Steam MS PC5 Pressure Fisher

  • Marshall Town, April 1981 S. Deshmukh (MS)

Controller for Controller 4160 Iowa 2

MS V6 In Process To l

j Resnote Transmitter Pressure Rosemont Wyle Labs November 1981 S. chose

[

Shutdown Transmitter ll53D lluntsville, Ala.

Panel' A,D,H,G

  • To be determined by Fisher j

for test Westinghouse or Wyle Labs.

i l

i i

i i

4 4

C

'g

_-