Forwards Documents Re TVA Program on Hydrogen Effects & Control in Facility Containment Per Hg Parris 801104 Request
ML19345D435
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/11/1980
From: Cross J
TENNESSEE VALLEY AUTHORITY
To: Tedesco R
Office of Nuclear Reactor Regulation
Shared Package
ML19345D436 List:
References
NUDOCS 8012150107
Download: ML19345D435 (2)


Text

500A Chestnut Street Tower II December 11, 1980 Z

i Mr. Robert L. Tedesco .? ...

Assistant Director for Licensing .' '

^

Division of Licensing U.S. Nuclear Regulatory Cc=missicn Washington, DC 20555

Dear Mr. Tedesco:

In the Matter of ) Docket No. 50-327 Tennessee Valley Authority )

In respense to your letters to H. G. Parris dated November 4, 1980, and December 9,1980, enclosed are the following documents related to the TVA program en hydrogen effects and control in the Sequoyah Nuclear Plant (SNP) unit 1 containment.

Enclosure 1: Quarterly Report on SNP Research Program en Hydrogen Combustion and Control Enclosure 2: A revised volume 2 of the Sequoyah Core Degradation Program Report Pursuant to paragraph 2.B.(22)D.(3) of the Sequoyah Nuclear Plant Unit 1 Operating License DPR-77, TVA submits the first quarterly report concerning the hydrogen effects and control research program (Enclosure 1). The quarterly report provides additional material in response to your letter of November 4, 1980. Also provided by Enclosure 1, section B, is TVA's response to item 1, a temperature profile for equipment survivability, as requested by'your letter to H. G. Parris dated December 9, 1980. The other four items will be addressed .n our scheduled meetings with your staff en December 15 and 18, 1980, and aill be submitted by December 16, 1980. The requested technical specifications and procedures for your review will be submitted by December 18, 1980. q f'9 s '

f'I 8 0.1215 0 k Q 9 g5

~

THIS DOCUMENT CONTAINS L POOR QUAllTY PAGES

.J

2 Mr. Robert L. Tedesco December 11, 1980 Enclosure 2, section VIII C, addresses an evaluation of the wall panels for I a pressure transient, an additional item of concern requested informally by your staff.

Very truly yours, TENNESSEE VALLEY AUTHORITY

'p./ 5 LW

'J. L. Cross Executite Assistant to the Manager of Pcwer Enclosures (10)