ML19345D389

From kanterella
Jump to navigation Jump to search
Part 21 Rept Re Westinghouse Gate Valve Failure to Close Under Test Conditions Less Severe than Design Specs, Initially Reported on 801030.Cause Is Unknown.Final Rept Will Be Submitted Upon Determination of Resolution
ML19345D389
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/24/1980
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-80-320-000 NUDOCS 8012150035
Download: ML19345D389 (3)


Text

al iautu 13 a mxi n FWU mfi it M!L L .l i - n@ m U +1

%O Cacb

~

PART 21 IDBEIFICATIOM NO. So- 320-oco CTPANY (WEJe<*ri 4 Cws Opp DATE OF IIITER_ d26ltro DIKET NO. 6-y 6 h j DATEDISTRIBlHED idE to A m - _ ORIGli!AL REPORT % SUPPLF5NNTARV DISTRIBUTION:

s 2

ea

.J f

REACTOR (R) a

% FEL CYCLE & SAFEGUARDS,(S) 1

  • . -, , m PATERIALS OD IE FILES EES IEFILES AD/SG AD/FFFEI AD/ROI EGIONS I,II,III,IV,V REGIONSI,II,III,IV,V REGIONSI,II,III,IV,V T

VStOR BR. R-IV VEEOR BR. R-IV VENDOR BR. R IV LEB / FPA FIG 5715 ffSS/FCES SS-395 NPS/D3L AEOD FIB 7602 LOEB/FPA F135715 g,ES / SG SS-881 NRR/ DOE Ac0D FIS 7602 LDEB/FPA MG 5715 NRR/DSI ASLBP E M 450 AEOD FIG 762 ta W T -

SAP /SP fi'B-7210A ASLBP E/W 450 NRR/ DOL -

CSEPAL FILES 015 CBHPAL FILES 016 EN 450

~

ASLBP CENiPAL FILES ( GRON) CBUPAL FILES (GR0io CBERAL FILES 016 PDR CENTPAL FILES SS-395 CENTRAL FILES (GR0fD LPDR PDR PDR TEPA LPDR LPDR TERA m[fsb '

ACi!0[{:

PRELIMINARY EVALUATION OF THE' ATTACHED REPORT INDICATES LEAD RESPONSIBILITY FOR FOLLOWUP AS SHOWN BELOW:

IE K ,NRR2 ffES [ OTHER _

EES 8012750030 s. Pa'. 8/1/80 Mnhc id r.lto

TW.c. \b4 Ta- -[.b b b -Mo - eso c

== SOUTH CAROLINA ELECTRIC a gas COMPANY POST C F FsCC 90 764 CotunsiA. Souin CAnctiwA esais ,

T. C %cwots.JR.

v.co.u.u., .- s . tne ,= November 25, 1980 u.ea.. cn..

Mr. James P. O'Reilly U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 3100 Atlanta, GA 30303

Dear Mr. O'Reilly:

Subject:

Virgil C. Summer Nuclear Station, Unit 1 Docket No. 50/399 Reportable Su ,bstantial Safety Hazard Westinghouse 3" Gate Valve Closure Failure On October 30, 1980, Mr. John Rausch of NRC Region II was informed by means of a telephone call of a potential significant deficiency.

During Hot Functional Testing, 10 Westinghouse 3" gate valves failed to completely close under test conditions which are less severe than the equipment specification design conditions. The valves stroked to significantly restrict flow, but the full stroke was not accomplished to trip the " closed" positfen indicati:n contcets in the motor operator or to seat the valve disc within the valve body.

Failure of these valves to close completely could impair the ability of_the plant to operate or shutdown safely. Under the South Carolina Electric and Gas Company program, we are reporting-this as a. substantial safety hazard as defined by 10CFR21.

am Westinghouse and SCE&G are working concurrently at Summer Station on a solution which will be tested prior to issuance of a generic response by Westinghouse. This is an interim report and a final report vill be sent when an adequate solution is achieved.

If you have any questions, please contact us.

Very truly yours,

/

r ,

T. C. Nichols, Jr.

NEC:rm e

e 1

i

Mr. James P. O'Reilly j Page 2 4-4 4

CC: Messrs. V. C. Summer

{ G. H. Fischer E. H. Crews, Jr.

D. A. Nauman

! O. S. Bradham J 0. W. Dixon R. B. Clary W. A. Williams, Jr.

J. B. Knotts, Jr.

J. Skolds B. Bursey NPCF/Whitaker File s

U. S. Nuclear Regulatory Commissions #

Office of Inspection and Enforcement i Washington, DC 20555 U. S. Nuclear Regulatory Commission

, Document Management Branch Washington, DC 20555 .

i

! 1 5

e-b e

l f'

i 1

f b

O e