Ack Receipt of Informing NRC of Steps Taken to Correct Deviation Noted in QA Program Insp Rept 99900209/80-02.Addl Info Required Re Welding Operator Performance Qualifications
ML19345B936
Person / Time
Issue date: 11/12/1980
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Becksted W
BERGEN-PATERSON PIPE SUPPORT CORP.
Shared Package
ML19345B937 List:
References
REF-QA-99900209 NUDOCS 8012020792
Download: ML19345B936 (1)


Text

m i

@p s;gO f4 UNITED STATES

+4 NUCLEAR REGULATORY COMMISSION

-f REGION IV

/[

5 *.-

6119YAN PLAZA DRIVE. SUITE 1000 ARUNCTON, TEXAS 76011 -

12 NOV 1980 Docket No.

99900209/80 Bergen-Paterson Pipesupport Corporation ATTN: Mr. W. F. Becksted Manager, Quality Assurance 48.Winnisquam Avenue-Laconia, NH 03246 Gentlemen:

Thank you for your letter.of October 14, 1980, in response to our letter dated September 10,_1980. As a result of our review, we find that additional information as discussed with you during a telephone call on November 7, 1980, is needed.

Specifically, for Item C: you reference QW-305 as being used for welding operators performance quali-fications.

Friction welding is not addressed-by Section IX of the code, therefore, the requirements of code case (N-55) are imposed. _N-55 states,

="The performance qualifications for inertia welding operators shall dupli-cate the_ test samples, test specimens, and requirements of the welding procedures specification." Therefore, please respond by stating your correc-tive actions, actions taken to prevent recurrence, and the dates by which these actions will be complei.ed.

Please provide this additional information within twenty (20 ) days in order that we may complete our review in a timely manner.

Sincereli U dis t

v Vendor Inspection Branch y3 W

?!

0-l'5 n,,3 35 tw 2

pd

'"5 si 5