Inquiry Rept 50-29/72-100:on 721113,bolt Observed Lying on Top of Lower Core Support Plate During Performance of Control Rod Interchange.Cause Not Stated.Lower Core Barrel Removed.Written Rept to Be Submitted within 30 Days
ML19345A801
Person / Time
Site: Yankee Rowe
Issue date: 11/14/1972
From: Loibl E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
References
50-029-72-100, 50-29-72-100, NUDOCS 8011250224
Download: ML19345A801 (3)


Text

. _ _ _

s..

-u

'o 9

g, UNITED STATES

/,T %,

ATOMIC ENERGY COMMISSION

)

f.N q ;

DIR ECTO R ATE OF' REGU LA TO R Y OPER ATIONS l

g*

REGION 9 Nb j,

  • f)l

%, QN 970 DROAD STREEr NEWARK. NEW JERSEY 07102.

l j

omie

(

. :2

-l RO Inquiry Renort No. 50-29/72-100

~i 3

Licensee:

Yankee Atomic Electric Company

.g k

License No.:

DPR-3 1j Facility:

Yankee Rowe - PWR ij Descriptive

Title:

Type "B" - Loss of Facility 4

Prepared by:

(-

c(

8 V

Z i

E. R. Loibl, Reactor Inspector

/ afe D

)

-l A.

Date and Manner AEC was Infor.ned:

a 4

November 13, 1972, by telephone call from the licensee.

B.

Description of Particular Event or Circumstance:

i Vnile performing the control rod interchange during tiie present scheduled outage, it was observed that a bolt was lying on top of the lower core support plate'.

Observations made with a T.V.

camera through 40 feet of water indicated that there were two j

additional bolts lying loose. An examination of the bolts indi-cate that they are control rod shroud tie down bolts..

Preliminary determination identifies two shroud' tubes displaced.

There are a total of 32 shroud tubes, 8 for shim rods and 24 for moveable control rods. All T.V. monitoring has been recorded on tape.

(

C.

Action by Licensee:

1 1.

The licensee has contacted Westinghouse to assist in conduct-ing a detailed internal inspection which includes removal of the lower core barrel.

s 2.

The core was completely unloaded on November. 11, 1972. This includes all fuel, control rods and sources.

-aysq 8011250 M V f

3 1

(.

(_

i 3.

The Plant Operating Review Committee has met and reviewed the j

problem.

1 4.

The Nuclear Audit and Review Committee has'been informed and corporate officers have been notified and have been on site.

I, i

5.

The plant will remain shutdown for an undetermined time.

6.

A written report will be submitted to the AEC within 30 days in accordance with 10 CFR 20.405.

j h.

1 i

A i

I s

t

[

f 1

i e

l i

I 1

i l

j e' j.

t

+

j.

-p y-

.-r--

r-

..- w y e

m g

I.

~

u r

i g p v -

.py

.4 y

4

.u c

y 3

t-A s

w m.

.. =

u}

5l.

'c'

..,r.

.f

    • l s

s q

s_.

.y.

. '. 4 i ;,v

v.

. r.

-r r

~

,.. L 7.N-.

+

n.

y A

MEMO ROUTE SUP Forrn AEC-9) (Rev. May 14.1947) AECM 0240 Sa ** * *at ta'*-

F a' ' = """"-

Fa' act'a-Note and return.

For si eatu e.

For informa tion.

t r

10 (s.,n..n nt:3 immus atuaans RO TNOUTRY RFPORT NO. 50-29/72-100- YANKEE ATOMIC J. G. Keppler, y

RO (2) o^u n vcTnTc c0MPANY - The subiect inouiry report is for F.

,..,,.a n a re a,.nup <-forn, tion.

Inspection covernee vi

.4 yo cu

,n.....nn>

inmus at"^ars cc: RO:E (5) hn provided at the site at the appropriate time. Ye

. entral Files Reg. Standards (2 )

office will be kent in.forned of significant develop-Dir. of Licensing (,3 )

-aate.

Dietrib'utinn will be nade by this office to TO (Heme and tnat)

INinAL,3 ptMARKs the PDR. LPDR. NSIC, DTIE and State representatives h./

5^"

after review by the licensee for proprietary infor-

/. C '-

"NPiON.

FROM t' lam. a M unst)

  1. EM AAKs tv R. T. Carlson, Chief.

Reactor Operations Br., RO:I P,eong perl LATJ f p

////6/7k ne omt. s.cc ron.como.t n,us l

g

.=

i o f,',I f'

a s' f/