g 4
NSD NORTHERN STATES POWER COMPANY MIN N E A PO LI S. MI N N E S OTA 55401 August 14, 1980 Mr. James G. Keppler Director, Region III Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137
Dear Mr. Keppler:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 and 50-306 In response to IE Bulletin No. 80-19, no relays of the type described are in use in reactor protection systems at this facility.
Yours truly, D. E. Gilberts Vice President Power Production cc:
Mr. G. Charnoff Director, U. S. Nuclear Regulatory Commi % ion Division of Reactor Operations Inspection Office of Inspection and Enforcement Washington, D. C.