-Tir NSIC ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 UTTLE ROCK. ARKANSAS 72203 (501) 371-4000 June 27, 1980 1-060-23 2-060-32 Mr. K. V. Seyfrit, Director Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission Region IV 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011
Subject:
Arkansas Nuclear One - Units 1 and 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 IE Bulletin 80 Examination of Containment Liner Penetration Welds (File:
1510.1 and 2-1510.1)
Gentlemen:
Following is our response to specific items of IE Bulletin 80-08.
Item 1:
" Determine if your facility contains the flued head design for penetration connections, or other designs with containment boundary butt weld (s) between the penetration rie--e and pro-cess piping as illustrated in Figure NE 1120-0.
nter 1975 Addenda to the 1974, and later editions of the $SME B&PV Code."
Reply:
Both ANO Unit 1 and Unit 2 utilize the flued head design for containment penetrations.
All such penetrations are listed in Attachments I and II.
Item 2:
If an affirmative answer is reached for Item 1, determine the following:
Applicability of the ASME Code, including year and ad-a.
denda and/or Regulatory Guide 1.19.
b.
Type of noudestructive examinations performed during construction.
l 8009020 y,ymmmu, som umtea,,, rey
i c.
Type of weld joint (including pipe material and size) and whether or not backing bars were used.
d.
Results of construction nondestructive examinations, i.e.,
if repairs were required.
This should be iden-tified including extent of repairs and description of defects encountered during repair, if known.
Reply:
a.
The applicable codes indicated on Attachments I and II.
b.
All flued head penetrations at ANO Unit I and Unit 2 were radiographed.
c.
All welds are butt welds, without backing bars.
Material and size information is contained in Attachments I and II.
d.
See Attaenment III and IV.
Item 3:
"For those facilities committed during construction to perform volumetric examinations of such penetrations through SAR commitments which have not performed radiography, justify not performing radiography or submit plans and schedules for performing radiographic examinations."
Reply:
As stated in response to Item 2b, all such welds at ANO were radiographed. Therefore, this item is not applicable.
^
As noted in our letter from Mr. J. P. O'Hanlon to Mr. G. L. Madsen, dated May 27, 1980, our investigations revealed one flued head pene-tration weld which had not been repaired to correct a lack of fusion defect identified during construction.
This defect has been repaired.
Very truly yours,
.bm e'.%,.JA David C. Trimble Manager, Licensing DCT:DRH:nak Attachments O
Page 1
ANO - UNIT 1 FLUED HEAD PENETRATIONS PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED P-1 ASTM A-155 36" USAS 1331.7, 1969 NO GR. KCF-70 CL. 1 P-2 ASTM A-155 36" USAS 1331.7, 1969 NO GR. KCF-70 CL. 1 P-3 ASTM 18" USAS 1331.7, 1969 NO A-106B P-4 ASTM 18" USAS 1331.7, 1969 YES A-106B P-5 ASTM 8"
USAS 1331.7, 1969 YES A-312, TP 304 P-7 ASTM A-376 or A-312 3/4" USAS 1331.7, 1969 NO TYPE 316 P-8 ASTM A-376 or A-312 2 "
USAS 1331.7, 1969 NO TYPE 316 P-9 ASTM A-376 or A-312 1" USAS 1331.7, 1969 YES TYPE 316 i
P-10 ASTM A-376 or A-312 3/4" USAS 1331.7, 1969 NO TYPE 316 P-11 ASTM 2"
USAS 1331.7, 1969 YES A-106B P-12 ASTM A-376 or A-312 1" USAS 1331.7, 1969 NO TP-304 P-13 ASTM A-376 or A-312 2 "
USAS 1331.7, 1969 NO TYPE 316 P-14 ASTM A-376 or A-312 2 "
USAS 1331.7, 1969 NO TYPE 316 P-15 ASTM A-376 or A-312 2\\".
USAS 1331.7, 1969 NO TYPE 316 P-16 ASTM A-376 or A-312 2" USAS 1331.7, 1969 NO TYPE 316 P-17 ASTM 4"
USAS 1^?1.7, 1969 NO A-106B P-19 ASTM 8"
USAS 1331.7, 1969 NO A-312,TP-304 P-21 ASTM 10" USAS 1331.7, 1969 NO A-106B P-22 ASTM 10" USAS 1331.7, 1969 NO A-106B P-23 ASTM 8"
USAS 1331.7, 1969 NO A-312, TP-304 P-24 ASTM 2"
USAS 1331.7, 1969 NO A-106B
Page 2
ANO-UNIT 1 (Continued)
PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED P-25 ASTM 1"
USAS 1331.7, 1969 NO A-106B P-26 ASTM A-376 or 12" USAS 1331.7, 1969 NO A-312 TYPE 316 i
P-27 ASTM A-358 12" USAS 1331.7, 1969 YES Class I, TYPE 304 P-31 ASTM A-376 or 1"
USAS 1331.7, 1969 NO A-312 TYPE 304 P-32 ASTM A-376 or 1"
USAS 1331.7, 1969 YES A-312 Type 304 P-33 ASTM A-376 or 1\\"
USAS B31.7, 1969 N0 i
A-312 TYPE 316 g
P-34 ASTM A-376 or 2"
USAS B31.7, 1969 NO 3
A-312 TYPE 316 P-36 ASTM A-376 or 12" OSAS B31.7, 1969 NO A-312 TYPE 316 P-39 ASTM A-376 or 3"
USAS B31.7, 1969 NO A-312 TP-304 P-40 ASTM 3"
USAS B31.7, 1969 NO A-106B P-41 ASTM 1"
USAS B31.7, 1969 NO A-106B P-42 ASTM 3"
USAS B31.7, 1969 NO A-106B
]
P-43 ASTM 1"
USAS B31.7, 1969 NO A-106B
)
P-46 ASTM 1"
USAS B31.7, 1969 NO i
A-106B P-47 ASTM A-376 or 3"
USAS B31.7, 1969 NO A-312 TP-304 P-48 ASTM 3"
USAS B31.7, 19/3 NO A-106B P-49 ASTM 3"
USAS B31.7, 1969 NO A-106B P-51 ASTM 6"
USAS B31.7, 1969 YES A-106B 4
P-52 ASTM 8"
USAS B31.7, 1969 N0 l
-A-IC6B P-53 ASTM 2"
USAS B31.7, 1969 NO A-106B P-54 ASTM 8"
USAS B31.7, 1969 NO A-106B P-55 ASTM 10" USAS B31.7, 1969 No
'A-106B P-58 ASTM 4"
USAS B31.7, 1969 NO A-106B
. ~.
Page-3 ANO-UNIT.1 (Continued)
PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED P-59 ASTM 6"
USAS B31.7, 1969 YES A-106B P-60 ASTM 8"
USAS B31.7, 1969 NO A-106B P-62 ASTM 8"
USAS B31.7, 1969 NO A-106B P-63
. ASTM 10" USAS B31.7, 1969 NO A-106B P-64 ASTM 4"
USAS B31.7, 1969 YES A-106B P-65 ASTM 4"
USAS B31.7, 1969 YES A-106B P-66 ASTM A-358 14" USAS B31.7, 1969 YES CLASS I, TP-304 P-67 ASTM A-358 14" USAS B31.7, 1969 YES CLASS I, TP-304 P-68 ASTM A-358 4"
USAS B31.7, 1969 YES CLASS I, TP-304 e
.. ~
y
.m-m..=
p
Attachment II Page 1
ANO - UNIT 2 FLUED HEAD PENETRATIONS PENETRATION PIPE APPLICABLE REPAlR MATERIAL SIZE CODE REQUIRED 2P-1 SA-106, GR. B 38" ASME SECTION III-1971 N0 or SA-155 GR.
THROUGH 1974 SUMMER KCF-70 ADDENDUM 2P-2 SA-106, GR. B 38" ASME SECTION III-1971 N0 or SA-155 GR.
THROUGH 1974 SUMMER KCF-70 ADDENDUM 2P-3 SA-106 24" ASME SECTION III-1971 NO GRADE C THROUGH 1974 SUMMER ADDENDUM 2P-4 SA-106 24" ASME SECTION III-1971 N0 GRADE C THROUGH 1974 SUMMER ADDENDUM 2P-5 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-6 SA-376 or SA-312 2"
ASME SECTION III-1971 No TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-7 SA-106 3/4" ASME SECTION III-1971 No GRADE C THROUGH 1974 SUMMER ADDENDUM 2P-8 SA-376 or SA-312 3/4" ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-9 SA-106, GR. B 1"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-10 SA-376 or SA-312 6"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-11 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-12 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-13 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-14 SA-376 or SA-312 2"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-15 SA-376 or SA-312 6"
ASME SECTION III-1971 NO J
TP-316 THROUGH Ic74 SUMMER ADDENDUM 2P-17 SA-376 or SA-312 10" ASME SECTION III-1971 YES TP-304 THROUGH 1974 SUMMER ADDENDUM
Attachment II Page 2
ANO-UNIT 2 (Continued)
PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED 2P-18 SA-376 or SA-312 3/4" ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-19 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-304 THROUGH 1974 SUMMER ADDENDUM 2P-20 SA-106 GR. B 12" ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-21 SA-106 GR. B 12" ASME SECTION III-1971 YES THROUGH 1974 SUMMER ADDENDUM 2P-23 SA-376 or SA-312 10" ASME SECTION III-1971 NO TP-304 THROUGH 1974 SUMMER ADDENDUM 2P-24 SA-376 or SA-312 6"
ASME SECT;4i III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-25 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-27 SA-358 14" ASME SECTION III-1971 NO TP-304, CI.1 THROUGH 1974 SUMMER ADDENDUM 2P-29 SA-376 or SA-312 6"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-30 SA-376 or SA-312 3"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-31 SA-106 GR. B 2"
ASME SECTION III-1971 YES THROUGH 1974 SUMMER ADDENDUM l
2P-32 SA-106 GR. B 4"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-33 SA-376 or SA-312 2"
ASME SECTIQ III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-34 SA-376 or SA-312 2"
ASME SECTION III-1971 NO TP-316 THROUGH 1974 SUMMER ADDENDUM 2P-35 SA-106 GR. C 4"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM l.
Attachment II Page 3
ANO-UNIT 2 (Continued)
PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED 2P-37 SA-376 or SA-312 3/4" ASME SECTION III-1971 NO TP-304 THROUGH 1974 SUMMER ADDENDUM 2P-39 SA-376 or SA-312 2"
ASME SECTION III-1971 NO TP-304 THROUGH 1974 SUMMER ADDENDUM 2P-40 SA-106 GR. B 3"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-41 SA-106 GR. B 1"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-42 SA-106 GR. B 3"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-43 SA-106 GR. B 3"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-46 SA-106 GR. B 2"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-48 SA-106 GR. B 3"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-51 SA-106 GR. B 6"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-52 SA-106 GR. B 10" ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-55 SA-106 GR. B 12" ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-58 SA-376 or SA-312 2"
ASME SECTION III-1971 NO TP-304 THROUGH 1974 SUMMER ADDENDUM 2P-59 SA-106 GR. B 6"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-60 SA-106 or GR. B 10" ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-61 SA-376 OR SA-312 3/4" ASME SECTION III-1971 YES TP-304 THROUGH 1974 SUMMER ADDENDUM
~
Attachment II Page 4
ANO-UNIT 2 (Continued)
PENETRATION PIPE APPLICABLE REPAIR MATERIAL SIZE CODE REQUIRED 2P-62 SA-106 GR. B 6"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-63 SA-106 GR. B 12" ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-64 SA-106 GR. C 4"
ASME SECTICN III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-65 SA-106 GR. C 4"
ASME SECTION III-1971 NO THROUGH 1974 SUMMER ADDENDUM 2P-66 SA-358 24" ASME SECTION III-1971 NO TP-304, CI.1 THROUGH 1974 SUMMER ADDENDUM 2P-67 SA-358 24" ASME SECTION III-1971 NO TP-304, CI.1 THROUGH 1974 SUMMER ADDENDUM 2P-68 SA-376 or SP-312 4"
ASME SECTION III-1971 YES TP-304 THROUGH 1974 SUMMER ADDENDUM 4
y
Attachment III Page 1
ANO-UNIT 1 WELD REPAIRS PENFTRATION REASON FOR REPAIR
- ACCEPTED /
REASON FOR REJECTION REJECTED REJECTION P-4
- Porosity, 1
Accepted Incomplete Fusion P-5 Slaglines 1
Accepted P-9 Slaglines 1
Accepted P-11 Root Concavity 1
Accepted P-27 Root Convexity 1
Rejected Slaglines Slaglines, In-complete Fusion 2
Rejected Slaglines 3
Accepted P-32 Root Concavity 1
Accepted P-51 Slaglines 1
Rejected Incomplete Fusion 2
Rejected Incomplete Fusion 3
Accepted P-59 Incomplete Fusion, 1
Rejected Incomplete Fusion Slaglines 2
Accepted P-64 Surface Defects 1
Accepted P-65 Incomplete Fusion 1
Rejected Slaglines 2
Rejected Incomplete Fusion, Slaglines 3
Rejected Incomplete Fusion 4
Accepted P-66 Unknown 1
Rejected Unknown 2
Accepted P-67 Unknown 1
Accepted P-68 Incomplete Fusion, 1
Rejected Incomplete Fusion Slaglines 2
Accepted
- Specific repair methods for each defect are unknown.
.m.
t Attachment IV ANO-UNIT 2 WELD REPAIRS PENETRATION REASON FOR REPAIR
- ACCEPTED /
REASON FOR REJECTION REJECTED REJECTION 2P-31 Incomplete Fusion 1
Accepted 2P-61 Slaglines, In-1 Accepted complete Fusion 2P-21 Incomplete Fusion 1
Rejected Incomplete Fusion 2
Rejected Slaglines 3
Accepted 2P-17 Incompete Fusion 1
Rejected Incomplete Fusion 2
Rejected Slaglines 3
Accepted 2P-68 Incomplete Fusion 1
Accepted
- All repairs consisted of excavating the unacceptable portion of the weld and rewelding.