Text
-
O
/
%g UNITED STATES
4 feUCLEAR REGULATORY COMMISSION 3
WASHINGTON, D. C. 20546 e
C0lHONWEALTH EDISON COMPANY AND IOWA ILLINOIS GAS AND ELECTRIC CCMPANY DOCKET NO. 50-254 QUA0 CITIES NUCLEAR POWER STATION, UNIT NO. 1 AMENOMENT TO FACILITY OFERATING LICENSE Amendment No. 57 License No. OPR-29 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by Comonwealth Edison Company (the licensee) dated February 2,1978, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (1) that the activities authorf:ed by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations:
D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR i
Part 51 of the Comission's regulations and all applicable requirenents have been satisfied.
j 2.
Accordingly, the license is amended by changes to the Technical l
Specifications as indicated in the attachment to this license amend-ment, and paragraph 3.B of Facility Operating License No. DPR-29 is hereby amended to read as follows:
8.
Technical Scecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 57, are hereby incorporated j
in the license. The licensee shall operate the facility in j
accordance with the Technical Specifications.
,80082801%0
. 3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCL AR REGULATORY COPt1ISSION Thoma Ippolito, Chief Operating Reactors Branch d2 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance:
August 6,1980 i
o
,,.,,---.._.,.--n.,-,--,--._-e.,.
,.n,
O 4
ATTACHMENT TO LICENSE AMENDMENT NO. 57 FACILITY OPERATING LICENSE NO. DPR 29 DOCKET NO. 50-254 Revise Appendix B Technical Specifications by removing pages El.2/2.2-1 and E3.1-1 and replacing with the enclosed pages.
l i
l i
l t
{
il -
e QU;.0-C! TIES DPt:-19 E1.2/2,2 TJ.MPERATUP.2 !.lMITATIONS LI..U ~?NG COND!TIONS FOft OPERATION SUl!VElLt.ANCE REQL'mEMENTS SPECIFICATIONS Heated emeent from the plant shall meet the rollow.
Ambibnt river water temperature and disch:qc temperatures will be moi..:ored. Temperature sen-ing restricticas beyond a mixing zone 600 feet sors v.ill be used to defin the temi erature tecime downstream of the di:Tuser pipes:
above and below the plant. Mc:uarements irorn the sensors are telemetered into the s:ation control room A The normal daily and seasonal temperature and are recortied on a strip chart secorder.
' fluctuations that er.isted be:yre the addition of Fo r grmmm!M apimd-
~
heated emuent shall be mamt.uned.
600 fe:t downstream of the diffuser pipes, one temperature sensor is located in the discharge b:.y.
B.
The maxinium temperature rise at any time (or and two temp::rature sensors are located in the place) above natural ambient temperatures intake area to record amhient river temperature.
shall not exceed 5 F.
Temperature informailen collected from thi4 sysicm C. The rate of change of temperature due to is recorded.
heated efiluent from the diffuer pipes shall not
.igure. 1.shows the locations of tempera:ure exceed 2
- F per hour (during controlled changes in operation of the plant). This requirement need not be met during changes in the mode of condenser cooling.
l l
Amendment No. 57 E1.2 /2.2-1
)
i f
QUAD-CTIES DPR-29 E3.0 REPORTING REQUIREMENTS 3.1 Chlorine Effluent Reports A letter shall be sent to the Director of the Office of Nuclear A.
Reactor Regulation within 30 days after a limiting cerdition for operation is exceeded describing the occurrence and justifying corrective action.
A report shall be prepared annually describing the results of the l
B.
chlorine analyzing and monitoring program. This report shall be sent to the Director of the Office of Nuclear Reactor Regulation l
within 90 days after the end of a report period.
3.2 Temperature Limitations Upstream and downstream temperatures recorded in accordance with Section 2.2 will be reported in the annual operating report.
3.3 Fish Impingement Annual reports will' be empi12d on the results obtained from impingement Results of the eirectiveness of the diversion system will be reported.
counts.
3.4 Chemical Effluent Chemical usage will be documented in the annual operating report each calendar l
year.
Amendment No.
57 E3.1-1
6
~,-
/
UNITED STATES
[
%'i NUCLEAR REGULATORY COMMISSION
. a wasmwoTom. o. c. nosss
%,*****/
COMMONWEALTH EDISON COMPANY AND IOWA ILLINOIS GAS D ELECTRIC COMPANY DOCKET NO. 50-265 QUAD CITIES NUCLEAR POWER STATI0ft, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 52 License No. DPR-30 1.
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for mendment by Cormonwealth Edison Company (the licensee) dated Febi Jary 2,1978, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Cornisrion's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health l
and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; i
D.
The issuance of this amendment will not be' inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Spec-ifications as ir.dicated in the attachment to this license amendment and paragraph 3.B of Facility License No. DPR-30 is hereby amended to read as follows:
1 B.
Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 52, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.
1 l
1
~
\\.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMISSION lh
. homas ppolito, Chief Operating Reactors Branch #2 Division of Licensing
Attachment:
Changes to the Technical Specifications Date of Issuance:
August 6,1980 1
I I
l t
I
.___-._m
- - _ _y-_.,,.
ATTACHMENT TO LICENSE AMENDMENT NO. 52 FACILITY OPERATING LICENSE NO. DPR-30 DOCKET NO. 50-265 Revise Appendix B Technical Specifications by removing pages E1.2/2.2-1 and E3.1-1 and replacing with the enclosed pages.
i 9
w-n..
i QUAn-(TI:FS Di'::.V f(1.2/2.1 1:;f,'.M:::/.Til: !s I.!M11 Al ION
- SURVEIL 1).NCE ITEQUIRES!ENTS LIS11 TING CONDITIONS l'OI: OPEP.ATION SPECIFICATIONS Ambient river - 'er temperature and dici.arge Heated'e!!1uent from the p! ant sha!! meet the follow-temperatures v 'il be iconitou.d. Temi erature s6n-ing restrictions beyond a mixing zone 600 feet sors will be used to def.nc the temperaturc agirae downstream of the difruer pipes:
above and hvow the plant. Measure:r.cnts frein '.1::
sensors are teleme ured into the stati..n contrcl roo:a and are secorded en a strip chart recu.de.r.
A.
The normal daily :nd se::sonal temperature fluctuations that e:.is:ed befc,re the addition of W"" "" #
d 'W **
Y heated ef.luent shall be maintaincJ.
600 feet downstream nf the ditTaser pipes, one temperature sensor is located ist the discha ce bay, B.
The maximum temperature rise at any time (or and two temper::ture sensors are located in the place) above natural ambient temperatures
. I" * * * * '##d * * * ' * * *
- P * ' * "' '#-
shall not exceed 5' F.
Temperr. tere. information collected from this system C.
The rate of change of temperature due to
'is recorded.
heated effluent fra:a the diffuser pipes sha!! not Figure 2.21 shows the locations of temperature exceed 2* F per hour '(during controlled sensors.
changes in operation of the plant). This requirement need not be met during changes in the mode
.of condenser cooling.
l l
l l
l l
l Amendment No.
52 E1.2/ 2.2-1 l
i i
QUAD-CrT1Eus DPR 30 1
E3.0 REPORTING REQUIREMENTS 3.1 Chlorine Effluent Reports A letter shall be sent to the Director of the Office of Nuclear A.
Reactor Regulation within 30 days after a limiting condition for operation is exceeded describing the occurrence and justifying corrective action.
l A report shall be prepared annually describing the results of the B.
This report shall be chlorine analyzing and monitoring program.
l sent to the Director of the Office of Nuclear Reactor Regulation within 90 days after the end of a report period.
3.2 Temperature Limitations l
Upstream and downstream temperatures recorded in accordance with Section 2.2 will be reported in the annual operating report.
3.3 Fish Impingement Annual reports will be compiled on the results obtained from impin counts.
i 3.4 Chemical Effluent Chemical usage will be documented in the annual operating report each calendar l year.
l 1
E3.1-1 Amendment No. 52
_