PNO-TMI-80-044:800815,four Men Made Second post-accident Entry Into Reactor Bldg.Max Total Body Dose to Any Man Was Less than 300 Millirems.Some Damage to Wiring & Equipment Found
ML19344E205
Person / Time
Site: Crane 
Issue date: 08/15/1980
From: Ronald Bellamy, Jay Collins, Kalman G
Office of Nuclear Reactor Regulation
To:
References
PNO-TMI-80-044, PNO-TMI-80-44, NUDOCS 8008280057
Download: ML19344E205 (2)


Text

W ggi% WS $ Y,

August 15, 1980 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-TMI-80-44 This preliminary notification constitutues EARLY notice of events of POSSIBLE safety or public interest sicnificance.

The information Dresented is as initially received without verification or evaluation and is basically all that is known by NRC staff on this date.

Facil i ty: Metropolitan Edison Company Three Mile Island, Unit 2 Middletown, Pennsylvania Docket Number 50-320

Subject:

Second entry into TMI Unit 2 Rea.ctor Building Four men made the second post accident entry into the TMI Unit 2 reactor building at 10:42 A.M., August 15, 1980. The planned duration of the entry was 40 minutes.

After approximately 20 minutes inside the Reactor Building, one of t;he men became physically exhausted and requested to come out.

He and another man were directed to exit the reactor building.

The two remaining men exited the reactor building at 11:20 a.m.

All men were physically exhausted.

Exhaustion was attributed to the use of several layers of protective clothing, full face respirator, and 85 F to 90 F temperatures inside the reactor building.

Preliminary measurements, digital and pocket dosimeters, indicate that the maximum total body dose to any member of the entry team was less than 300 mr.

The entry team surveyed the 305' elevation (ground level) and the 347' elevation (refueling floor).

Gama readings on the 305' elevation were 400-700 mr per hour in shielded areas.

The average gamma readings on the 347' elevation were between 100 and 300 mr per hour. A teletector reading 12' from the reactor head indicated 150 mr.

The entry team energized the reactor building lights and approximately 50% of the lights illuminated.

The reactor building sump water was observed to be murky with floating debris.

Some electric wires on the 347' elevation were very brittle and crumbled when touched. A standard black telephone was melted and defomed almost beyond recogni tion.

A 55 gallon drum with the top cover still attached was crushed.

Numerous rusted surfaces were observed, however the reactor head appeared to be in good condition.

Prior to the four man entry, the reactor building was purged beginning 9:15 a.m.

on August 14, 1980, and teminated at 9:25 a.m. on August 15, 1980.

Approximately 85 curies were released to the atmosphere.

After purging, the bu concentration was less than the MPC in a restricted area (1 x 10 g1 ding airuCitcc) Kr-85.

Bechtel Corporation has been contracted to continue with the work inside the reactor building.

The date for the next entry has not been decided.

Media interest has occurred because of licensee issuance of a press release.

The Commonwealth of Pennsylvania has been informed.

The NRC has not made plans to issue a press release at this time.

s This preliminary notification is issued for information only and no further action by the NRC is anticipated.

80082800$?

PriO/TMI-80-44 The NRC TMI Program Office received notification of this occurrence by monitoring r ed and this informati n was current as of 2:30 p.m.JBmT T &

events as they o[c R. p.F wr W. p. swh

Contact:

,jffa man 3

G.

590-3957 R. Bellamy 590-3957 J. Collins 590-3955 Di s tribution:

(Facsimile Transmission Times Noted)

H St Bldg 3.'.3 7 ChairTnan Ahearne Commissioner Bradford S. J. Chilk, SECY Coninissioner Gilinsky Commissioner Hendrie C. C. Kammerer, CA ACRS (For Distribution)

MNB Bldg 2.' Y.l.-

P. didg 8'M7 IE:X0053.'.34IE:HQ Dist. )

W. J. Dircks, ED0 H. R. Denton, NRR C. tiichelson, AEDO D. Ross, NRR J. J. Fouchard, PA R. J. Mattson, NRR Landow Bldg (Fax by HQ)

N. M. Haller, MPA S. Hanauer, NRR (6 min /page)

W. Kerr, OSP D. Eisenhut, NRR J. J. Cunmings, 01 A H. K. Shaper, ELD R. H. Vollmer, NRR B. J. Snyder, NRR (MAIL)

Region I 2.TJ' R. Minogue, SD Region II d'O-O Willste Bldg IE:XOOS Region III M*af J. G. Davis, NMSS Document Management Br Region IV 4'/O R. Budnitz, RES (For PDR/LPDR)

Region V W/r PRELIMINARY NOTIFICATION 1

I l

l