ML19344D845

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 80-18, Maint of Adequate Min Flow Through Centrifugal Charging Pumps Following Secondary Side High Energy Line Rupture. No Action Required
ML19344D845
Person / Time
Site: Atlantic Nuclear Power Plant 
Issue date: 07/24/1980
From: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Collier A
OFFSHORE POWER SYSTEMS (SUBS. OF WESTINGHOUSE ELECTRI
References
NUDOCS 8008260123
Download: ML19344D845 (1)


Text

l c Guru

'g t'NITED STATES

(

8 NUCLEAR REGULATORY COMMISSION c,

f nE REGION ll e[

101 MARIETTA ST., N.W., SUITE 3100 e,

AT LANTA, GEORGIA 30303 n

In Reply Refer To:

JUL 2 41980 PO s

50-437 Offshore Power Systems ATTN:

A. R. Collier, President P. O. Box 8000 Jacksonville, FL 32211 Gentlemen:

The enclosed IE Bulletin No. 80-18, is forwarded for your information.

Although no written response is required at this time, these concerns will be addressed as part of the licensing process for your plant. If you desire addi-tional information regarding this matter, please contact this office.

Sincerely,

(~

)

fames P. O'Reilly0 Director

Enclosures:

1.

IE Bulletin No. 80-18 w/encls 2.

List of Bulletins Recently Issued 4

8008200/2 3

SSINS No.: 6820 Accession No.:

UNITED STATES 8005050062 NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION Ah3 EhTORCEMEhT WASHINGTON, D.C. 20555 July 24, 1980 IE Bulletin No. 80-18 MAINTENMCE OF ADEQUATE MINIML'1 FLOW THRU CENTRIFUGAL CHARGING PUMPS FOLLOWING SECONDARY SIDE }ilGH ENERGY LINE RUPTURE Description of Circumstances:

Letters similar to the May 8, 1980 notification made pursuant to Title 10 CFR Part 21 (enclosure) were sent from Westinghouse to a number of operating plants and plants under construction (list, within enclosure) in early May, 1980.

The letters and the enclosed "?. ort 21" letter contain a complete description of the potential problem swunarized below. The letters indicated that under certain conditions the centrifugal charging pumps (CCPs) could be damaged due lack cf minimum flow before presently applicable safety injection (SI) 6ermination criteria are met. The particular circumstances that could result in damage vary somewhat from plant to plant, but involve unavail-ability of the pressurizer power operated relief valves (PORVs), with operation of one or more CCPs repressurizing the reactor during SI following a secondary system high energy line break. Since the SI signal automatically isolates the CCP mini-flow return line, the flow through the CCPs is determined by the individual pump characteristic head vs. flow curve, the pressurizer safety valve setpoint, and the flow resistant.es and pressure losses in the piping and in the reactor core. That minimum flow may not be adequate to insure. pump cooling, and resulting pump damage could violate desi p criteria before current SI termination criteria are met.

Westinghouse recommends that plant specific calculations outlined in the letter (enclosure) be performed to determine if adequate minimum flow is assured under all conditions. If adequate minimum flow is not assured, Westinghouse recommends specific equipment and procedure modifications which will result in adequate minimum flow. The recommended modifications assure availability of the necessary minimum flow by assuring that the mini-flow bypass line will be open when needed, but will be closed at lower pressures when the extra flow resulting from bypass line closure might be necessary for core cooling.

i DUPLICATE DOCUMENT Entire document previously entered into system under:

ANO 50C@ G 2

.t

,l No. of pages:

r

'*