ML19344D241

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 80-003/01x
Date released: 12/24/2019 Download: ML19344D241


Updated LER 80-003/01x-1:on 800109,during Eddy Current Test of Tubes in Unit 2 Steam Generators,Indications of Tube Degradation Were Seen.Caused by Corrosion.Several Tubes Plugged & One Removed for Further Examination
ML19344D243
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 03/06/1980
From: Hunstad A
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19344D243 (50)
Forwards Updated LER 80-003/01x
ML19344D240
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 03/06/1980
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19344D240 (1)