A Metropolitan Edison Company Post Office Bc4 480 g

Middletown, Pennsylvanis 17057 717 944 4041 Writer's Direct Dial Nurnber August 20, 1950 TLL 406 TMI Program Office Attn:

Mr. John T. Collins, Deputy Director U. S. Nuclear Regulatory Commission c/o Three Mile Island Nuclear Station Middletown, Pennsylvania 17057

Dear Sir:

Three Mile Island Nuclaar Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 RCS Water Chemistry and Corrosion Control On July 11, 1900, we responded to two (2) specific concerns identified by the NRC concerning the control of dissolved 02 in the RCS water. In that letter, TLL 318, we identified that the results of analyses performed to verify the recombination of H /02 and a gamma flux field, would be provided at a later 2

date.

This letter transmits the results of the analysis.

l Sincerely,

';. K. Hovey Director, TMI-2 GKH:LJL: dad cc: