mummumomsummmumemmx,-roo-c4 6ihr+,tCommonwe.
PART 21 IDBRIFICATION NO.
to - 3e-oo1 CCFPANY RVE_frenden (
DATE OF llt itK_ ididte DOCKET NO. b3AB DATE DISTRIELriED i aln to c.m ORIGIRAL E ORT SUPPLB OITARY L w
f _7
?
DISTRIBUTION:
IS T
T n
REACTOR (R) L FUEL CYCLE &
SAFEGUARDS (S) 2 i
f ATERIALS (FD l
IEFILES
- 1-mim EES m',m, IEFILES AD/SG AD/FFFEI AD/ROI PEGIONS I,II,III,IV,V REGIONS I,II,III,IV,V PEGIONSI,II,III,IV,V VSOJR BR. R-IV VB03R BR. R-IV VENDOR BR. R IV LDEB / FPA FI'8 5715 tbES/FCFE SS-395 NRP/ DOL AEOD FIG 7602 LOEB/FPA f,1,3 5715 g.SS / SG SS-881 SFR/ DOE AEOD FIS 7502 LDEB/FFA FIG 5715 N?NDSI ASLEP Ehl 450 AEOD FIB 7602 NMT SA /SP fia-7210A ASLBP Ehl 450 NRR/ DOL Ola CENTPAL FILES 016 CENTPAL FIES ASBP M 450 CENTRAL FILES ( GRom CBURALFILES (GR0iG l
CSiiRAL FILES 016 PDR CS4TRALFILES SS-395 CBsTPAL FILES (GPJD LPDR PDR PDR TEPA LPDR l
LPDR TERA Y
l P22 [333$'
AC" FRELIMINARY EVALUATION OF THE' ATTACHED REPORT ItOICATES LEAD RESPONSIBILITY FOR FOLLOWJP AS SH]hil BELOW:
~~~ Z NRP NFSS IE OTHER 1
1 EES 8332240 M
%,\\ ea Pa'. 8/1/80 a.,
itJthe
o ne Par & r.i a
- e:>-si3 ee Gilb, art /Commonwsalth engineens enc :nse.aw g
GILEEAT ASSOCIATES. IC, P. O. B:x MSS. Reading. PA iSEC3/Te. 2".5 775 2530/ Cable Gitasoc/ Telex S35-431 53-Mb December 11, 1980 United States Nuclear Regulatory Commission Region I 631 Park Avenue Ring of Prussia, PA 19406 ATTENTION:
Mr. Boyce H. Grier Director SUEJECT:
Potential Reportable Event -
Component Cooling Pump Control Circuitry
Dear Mr. Grier:
In accordance with 10CFRZ1 require:ents, this is to document that
. Mr. S. D. Ebneter of Region I was notified by telephone on December 10, 1980, at approximately 8:15 a.m.,
of a potential reportable event.
Name of Individual k*no Reported Stephen J. Torna - Manager, Inspection & Material Services, who was acting for the Quality Assurance Division General Manager, made the call.
Activity Involved Gilbert Associates, Inc. (GAI) design of control circuitry for component cooling pump.
Components Involved Not applicable.
Facility Involved V. C. Summer Nuclear Station, Unit 1, being constructed by the South Carolina Electric & Gas Cocpany.
525 taxas'ar A,enue, Readeg FA.WorsacL1.s P:st Geni kas. Reedag PA 2t5 77526:0 209 (ast Wassegten Avenue, ackson. Mi 517 7E? rJ0C BC 8M 5:reet hem.Yo t, NY Ft2 482448C
[/ Gilbert /Cimmortweilth sym me wi.==
', r ur es: ens =:. e c h.vu n.e. en sc 1. rs Smt c s =N p
US Nuclear Regulatory Co ission December 11, 195C Mr. B. H. Grier Page 2 N. R. Barker Nature of Defect An interlock contact was not provided in the control circuit of the swing pu=p, which prevented it frc startin; on a lead sequencer signal when it was lined up as the pri=at; pimp.
This error was discovered and docu=ented during routine testing.
The safety hazard which could be created by failure of the pump to start, is possible loss cf cc=penent cooling water.
Date Infor=ation Obtained A written report indicating this to be potentially reportable, j
was received by the Quality Assurance Division on Decenber 4,1980, from GAI Engineering.
Corrective Action The circuitry has been redesig-ed to include an "af terstart" from pump "C" across the cell switch of pu=p "A" and pump "B" in the "C" pu=p "A" and "B" channels breaker start c r:"*?ry.
~
We have determined that this cenditien does not exist on any of our other design projects.
No further action is planned.
if you require any further infernatien on this matter, please contact ce at (215) 775-2600, extension 2285.
Very truly.you,rs, in j
f l']1.f\\
,i fl R. 3.h?.KER
' { N.
General 'anager j
Quality Assurance Division cc:
H. Loren:
T. M. Demers V. Stello, Director, Office of Inspection & Enforcement - 3 copies Nuclear Regulatory Co==ission, Washington, D.C.