Text
.
g e
kg f em '.:: 61s U.S. NUCLE AR REGUL ATORY COMMISSION g cj[
"7 CERTIFICATE OF COMPLI ANCE For Racecactive Materials Package;
- 1. ' a i Ce tincave Number 1.(b) Revision No.
1.(c) Package identification No.
1.(d ) Pages No. 1.tel Total No. Pages 6375 9
USA /6375/B( )
1 P
- 2. P a E U.* B L E 2.' a i TNs ce tificate is issueo to satisfy Sections 173.393a.173.394.173.395 and 173.396 of the Decartment of Transportation Hazardous Mate <iais Accuistions (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Trar socria non r?ancerous Cargges Aequiations (46 CF R 146-149). as amended.
2 t)
The pac *a;inc and centents cescribed in item 5 below, meets the safety standards set forth in Sucpart C of Title 10. Code of F eocrat Regu!anons, Part 71. " Pac = aging of Raoicactive Materials for Transport and Transportation of Radicactive Material Under Certain Conostions.
2.'c)
This certificate ooes not relieve the consic.nor from compliance with any reouirement of the regulations of the U.S. Department of Transocrtation or other apolicable regulatory agencies. including the government of any country through or into which the package well be transported.
'is :emhcite 3 asved en the basis of a safety analysis report of the package design or application-3 :al Preparec by f.Name and address):
3.Ibl Title and ioentification of report or application:
Chem-Nuclear Systems, Inc.
Chem-Nuclear Systems, Inc. application P.O. Eox 1866 dated November 26, 1979.
Bellevue, WA 98009 71-6375 3.(c)
Docket No.
4 C O *.DITIO N S TNs ce tificate is conostional upon the fulfilhng of the reouirements of Subpart O of 10 CF R 71, as applicable, and the conditions specified in item 5 below.
$ Cescription of Pac = aging and Authorized Contents, Model Numoer. Fissile Class. Other Conditions. and Ref erences:
(a) Packaging (1) Model No.
CNS 4-45 (2) Description-A lead shield shipping cask, encased in mild steel on the outside and stainless steel on the inside.
The cask is cylindrical in shape, 173-1/8 inches long and 42-1/2 inches in diameter for all of its length except for a distance of 31-5/8 inches at each end which is 40-1/2 inches in diameter.
The principal shielding consists of 6-1/4 inches of lead.
A nine-inch thick impact limiter is attached to both ends of the Cask with four of the twelve, 1.25-inch cover bolts (each end of the cask has a cover).
The impact limiters are constructed by welding a bundle of 2-1/2 inch, 13 gage tubing between 1/4-inch SS plates and enclosing the bundle with a 1/16-inch SS shell.
The cask cavity is 26 inches in diameter by 159 inches in length.
The net weight of the cask is 57,050 pounds.
The gross weight, containing blanket fuel assemblies, is 67,050 pounds.
8012230 276
/..
Page 2 - Certificate No. 6375 - Revision No. 9 - Docket No. 71-6375~
5.
(a) Packaging (Cont'd)
- (3) Drawings The Model No. CNS 4-45 shipping cask is constructed in accord with the following Battelle Memor:al Institute Drawing Nos.:
9123-6PB-0001, Rev. B WI.itehead & Kales PB-1 Shipping Container 00-000-552, Rev. O Fuel Basket Container Assembly PRDC i
(b) Contents (1) Type and form of material I
Solid nonfissile irradiated hardware.
(2) Maximum quantity of material per. package i
e Maximum weight of contents, including any container, shall be 10,000 pounds.
As needed, appropriate component spacers shall be used in the cask cavity to limit movement of contents during accident.' conditions of transport.
6.
The cask shall be shipped dry.
7.
Pipe plugs may be used as seals for the pressure gage, vent and drain lines.
8.
Prior to each shipment, the packaging lid silicone 0-ring shall be inspected.
The 0-ring shall be replaced with a new silicone 0-ring if inspection.shows any defects or every twelve (12) months, whichever occurs first.
9.
The package authorized by this certificate is hereby approved for use under the l
general license provisions of 10 CFR 671.12(b).
10.
Expiration date:
November 30,.1981.
i 4
REFERENCE 4.
Chem-Nuclear System, Inc. application dated November 26,_1979.
FOR THE U.S. NUCLEAR REGULATORY. COMMISSION Charles E. MacDonald, Chief-Transportation Certification Branch' Division of Fu'el Cycle and-Material.Safetyc DEC 0 DEED Da e, 3
+
3
-g--
g-+g
- yfw y-ve g
- g
%g M13 P-9 g
-q l-*h*r 9
s eyMe--o--=*y
--W rr tw Wy eae.$
4"*+