U Form NRC-618 U.S. NUCLE AR REGULATORY CoMMISSloN CERTIFICATE OF COMPLI ANCE 10 C R 71 For Radioactive Materials *ackages 1.f al Certificate Number 1.(b) Revision No.
1.(c) Package identification Nr,.
1.(d) Pages No. 1.(e) Total No. Pages 6744 3
USA /6744/B( )
1 3
- 2. PRE AMBLE 2.ta)
This certificate is issued to satisfy Sections 173.393a.173.394.173.395. and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of tne oepartment of Transportation Dangerous Cargoes Regulatsons (46 CF R 146-149). as amended.
2.!bi The packaging and contents desenbed in item 5 below, meets the safety standaros set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71. " Packaging of Radioactive Materials for Transoort and Transportation of Radioactive Mater al Under Certain Conditions.
2.fc)
This certificate does not relieve the consignor from compliance with any reovirement of the regulations of the U.S. Department of Transportation or other aoolicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or apotication-3.f a)
Prepared by (Name and addresst 3.(b)
Title and ioentification of report or acolication:
Teledyne Energy Systems Protective Packaging, Inc. application dated ~
110 West Timonium Road March 25, 1975, as supplemented.
Timonium, MD 21093 71-6744 3.fc) oocket No.
4 CONDITIONS This certificate is conoitional upon the fulfilling of the recuirements of Subpart O of 10 CFR 71, as applicable. and the conditions specified in item 5 below.
- 5. cescription of Packaging and Authorized Contents. Mocel Nurnoer. Fissile Class, other Conditions, and
References:
(a) Packaging (1) Model No.:
6744 (2) Description The packaging consists of an overpack which provides thermal and impact resistance i
for an inner shielded cask.
Each packaging consists of an outer overpack of two concentric right circular steel cylinders with the annulus filled with 5 to 9 inches of polyurethane foam (U-2333) on the sides and 10.5 to 19 inches at the ends.
The overpacks are split in the mi6dle and joined by flanged i
closures to completely enclose the lead shielded inner cask.
The inner cask l
consists of right circular cylinder wit, steel-encased lead shielding and bolted, neoprene gasketed closure.
Thre.e (3) overpacks and eight (8) shielded l
[
casks comprise the authorized packaging.
Dimensions and maximum weights of the three overpacks are as follows:
l Overpack Dimensions Gross Weight (1bs) 32340-1 79.5" dia. x 105.7" high 35,000 32340-2 77.7" dia. x 100.4" high 35,000 32341 38.5" dia. x 76.5" high 6,500 I
801 2230 2 y
h.
Page 2 - Certificate No. 6744 - Revision No. 3 - Docket No. 71-6744 5.
(a) Packaging (continued)
(3) Drawings The overpacks and shielded casks are constructed in accordance with the following Protective Packaging, Inc. Drawing Nos.:
Package Overpack Shielded Cask 1
32340-1, Rev. B 32216-3, Rev. D 2
32340-1, Rev. B 32216-4, Rev. D 3
32340-2, Rev. B 32216-1, Rev. D 4
32340-2, Rev. B 32216-2, Rev. D 5
32340-2, Rev. B
- 32133, Rev. B 6
- 32341, Rev. B
- 32151, Rev. A 7
32340-1, Rev. D 109-55D0025, Rev. B 8
32340-2, Rev. D 109-5500024, Rev. B (b) Contents (1) Type and form of material Radioactive material, as solids, in normal or special form within lead l
shielded casks which are enclosed in an appropriate overpack.
(2) Maximum quantity of material per package Thermal decay heat not to exceed.10 watts for solids that will not-decompose at temperatures up to 300 F and 5 watts for.other solids.Fiss and Fissile Class specified in 10 CFR 971.11.
6.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 971.12(b).
7.
Expiration date:
November 30,.1985
4 8
Page 3 - Certificate No. 6744 - Revision No. 3 - Docket No. 71-6744 REFERENCES Protective Packaging, Inc. application dated March 25, 1975.
Supplements dated:
July 21, 1975; and July 2 and November 11, 1980.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
$ { Mu0.s.O j
k Charles E. MacDonald, Chief 0
Transportation Certification Branch Division of Fuel Cycle and Material Safety Date: