ML19343B244

From kanterella
Jump to navigation Jump to search
Forwards LER 80-054/03L-0
Date released: 12/23/2019 Download: ML19343B244


LER 80-054/03L-0:on 801110,failure of SI-661-CV Caused 21A Safety Injection Tank Level to Decrease to Less than 187 Inches.Caused by Solenoid Valve 2-CV-661 Leak.Solenoid Valve (ASCO-NP8320A175V) Replaced W/Spare
ML19343B245
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 12/10/1980
From: Rizzo P, Wenderlich R
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19343B245 (1)
Forwards LER 80-054/03L-0
ML19343B242
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 12/10/1980
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19343B242 (1)