ML19343B199

From kanterella
Jump to navigation Jump to search
Forwards Revision 1 of Farley Unit 2 Special Low-Power Tests Safety Evaluation, Performed by Westinghouse. Incorporates Changes of Ref 1 & Min Temp for Criticality
ML19343B199
Person / Time
Site: Farley Southern Nuclear icon.png
Issue date: 11/18/1980
From: Clayton F
ALABAMA POWER CO.
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML19343B200 List:
References
NUDOCS 8012150194
Download: ML19343B199 (1)


Text

/ Jab ma Power C;mpany 600 N rrtn 18tn Street Post Offic: Box 2641 Birmingh m. Atcama 35291 Telephone 205 250-1000 m

F. L CLAYTON, JR.

senior vice President Alabama Power the southern eerirc sortem November 18, 1980 Docket No. 50-364 q

Director of Nuclear Reactor Regulation

'.)

U. S. Nuclear Regulatory Commission Phillips Building, Room 116 7920 Norfolk Avenue Bethesda, Maryland 20014

,.l G

Attention:

Mr. A. Schwencer a

JOSEPH M. FARLEY NUCLEAR PLANT - UNIT 2 SPECIAL LOW POWER TESTS Gentlemen:

Enclosed is Revision 1 to the Farley Unit 2 Special Low Power Tests Safety Evaluation performed by Westinghouse. The revised safety evaluation incorporated the changes of reference I which proposed utilizing reactor coolant pump heat as the heat scurce for the Simulated Cooling with Loss of Power Conditions Test (501-7-006).

The revised minimum temperature for criticality was also incorporated into the revised safety evaluation.

If there are any questions, please contact us.

Yours very truly, d

  • , /

a 9 L. Clayton,;;Jr.

BDM:rt Enclosure cc:

Mr. R. A. Thomas Mr. G. F. Trowbridge w/ enclosure Mr. L. L. Kintner w/ enclosure Mr. W. H.

iradford w/ enclosure j

Mr. T. P 2pels w/ enclosure Mr. B.

.on w/ enclosure S

//

p 8 012150 lg