ML19343B175

From kanterella
Jump to navigation Jump to search
Forwards Proprietary & Nonproprietary Versions of CEN-123(A) Statistical Combination of Uncertainties. Describes Methods Used to Combine Sys Parameter Uncertainties in Thermal Margin Analyses for Cycle 2
ML19343B175
Person / Time
Site: Arkansas Nuclear 
Issue date: 12/01/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Clark R
Office of Nuclear Reactor Regulation
Shared Package
ML19262F332 List:
References
2-120-01, 2-120-1, NUDOCS 8012150097
Download: ML19343B175 (2)


Text

!

8 ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK. ARKANSAS 72203 (500 371-4000 December 1, 1980 3

3 2-120-01 y

~

Director of Nuclear Reactor Regulation

-M

[,$

ATTN: Mr. Robert A. Clark, Chief d

=

cE!

Operating Reactors Branch #3 e

Division of Licensing C

g g

=

U. S. Nuclear Regulatory Comm.

Washington, D.C.

20555

SUBJECT:

Arkansas Nuclear One - Unit 2 Docket No. 50-368 License No. NPF-6 CEN-139( A)-P, " Statistical Combination of Uncertainties", November,1980 (File: 2-1510)

REF:

(a) CEN-123(F)-P, " Statistical Combination of Uncertainties" Part 2, January,1980 (b) CEN-124(B)-P, " Statistical Combination of Uncertainties" Part 2, January,1980 Gentlemen:

This letter transmits forty (40) copies of CEN-139( A)-P (proprietary),

document numbers 000001 through 0000,0, and twenty (20) copies of CEN-139(A)-NP (non-proprietary), " Statistical Combination of Uncertainties". This report describes the methods used to statistically combine system parameter uncertain-ties in the thermal margin analyses for AN0-2 Cycle 2.

The report is similar to those listed as references A and B as submitted by Florida Power and Light (FP&L) and Baltimore Gas and Electric (BG&E),

respectively.

The overall statistical methods used in the ANO-2 report, CEN-139, are basically the same as those used in the Reference A and B reports.

However, the ANO-2 study incorporates plant design differences as well as experience gained from the BG&E and FP&L studies.

In particular (1) the fuel design and system parameter data bases for /140-2 are different than those for the BG&E and FP&L studies, (2) uncertainties for system parameters are based on ANO-2 as-built 16 x 16 fuel data rather than that for 14 x '14 fuel and, (3) the number of cases analyzed to determine the sensitivity of system parameters for the AN0-2 analysis was reduced based on C-E's experience gained from the BG&E and FP&L studies.

861&\\S$fYl MEMBEA M100LE SOUTH UTfuTIES SYSTEM

Mr. Robert A. Clark, Chief December 1, 1980 Due to the proprietary nature of the material combined in CEN-139(A)-P we request that it be withheld from public disclosure in accordance with the provisions of 10 CFR 2.790 and that this material be safeguarded.

The reasons for the proprietary classification of this report are delineated in the enclosed affidavit.

If any questions arise concerning the contents of the enclosed report, please do not hesitate to contact me.

Very truly yours, bY 0 YYb David C. Trimble Manager, Licensing DCT:PMH:1p 4