MSP NORTHERN STATES POWER COMPANY M I N N E A PO L.l e, M I N N E S OTA 55401 October 31, 1980
((
N, c) kI k
<,cc 4
,.2 v*s t,
2 o.,
u:
'Y Z * ' )
m CQ UbW'
$E R
~$
M to Mr. James G. Keppler un io Director, Region III Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137
Dear Mr. Keppler:
PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket Nos. 50-282 and 50-306 In our previous responses to IE Bulletin No. 80-08, we committed to radio-graphic examinations of two Unit 1 welds which were not previously radio-graphed. Examinations attempted during the refueling outage were unsuccess-ful due to the thickness of the associated steel (about 7.5 inches). As noted in our response of August 21, 1980, the subject welds had been examined ultrasonically and found acceptable. Documentation of the ultrasonic exani-nation shows that the test personnel were aware the backing rings were present.
Yours truly, D. E. Gilberts Senior Vice President Power Supply cc:
Mr. G. Charnof f Mr. C. D. Feierabend Director, Division of Reactor Construction Inspection U. S. Nuclear Regulatory Commission Washington, D. C.
20555 DEG:nk 80131,90 $
g 3 gi p