ML19341D719

From kanterella
Jump to navigation Jump to search
Forwards LER 81-019/01T-0.Vent Monitors Could Become Inoperable If Walls Collapsed During Seismic Event
Date released: 12/21/2019 Download: ML19341D719


LER 81-019/01T-0:on 810320,two Walls on Refueling Floor of Each Unit Found Unstable Under Effects of Dbe.Caused by Const or Design Error.Mods Completed to Walls.Mods Scheduled for Unit 3 Prior to Completion of Refueling Outage
ML19341D720
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 04/03/1981
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19341D720 (1)
Forwards LER 81-019/01T-0.Vent Monitors Could Become Inoperable If Walls Collapsed During Seismic Event
ML19341D718
Person / Time
Site: Peach Bottom Constellation icon.png
Issue date: 04/03/1981
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: GRIER R H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19341D718 (2)