ML19341C204

From kanterella
Jump to navigation Jump to search
Forwards Application to Amend License DPR-59,correcting Typographical Error in Tech Specs Table 4.6-1,Item 1.6 Re Inservice Insp of Pressure Containing Welds in Vessel Penetrations.Amend Fee Encl
ML19341C204
Person / Time
Site: FitzPatrick 
Issue date: 02/20/1981
From: Bayne J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: Ippolito T
Office of Nuclear Reactor Regulation
Shared Package
ML19341C205 List:
References
JPN-81-15, NUDOCS 8103020376
Download: ML19341C204 (2)


Text

'

POWER AUTHORITY OF THE STATE OF NEW YORK f

10 CotuMaus CIRCLE NEW YORK N. Y. tool 9 GEORGET. BERRY (2126 397 6200 oean'av'in's orrTc's'n TausTEEs JOHN W. 80$ TON JOHN s.OYSON na act ?&

arcTom GEomGE L. lNGALLs JOSEPH R. SC IEDER vecs cuaseMAN PAR CEh? & CMitF mtCHARD M. FLYNN

!,*c,*,'",c';^1.,,,,,,

no.E=T i. wit'oan February 20, 1981

'5" e

entsEnicx a. cuanx JPN-81-15

  • c,%',' " "^ "'

Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission G

Washington, D. C.

20555 52 r

?rl

': a Attention:

Mr. Thomas A.

Ippolito, Chief

'_ i a

Operating Reactors Brancn No. 2 7

y.

^j Division of Licensing

.2 gA a

csi W ci

Subject:

James A. FitzPatrickNuclearPowerPlantd

[

5s N

=

Docket No. 50-333 25 Proposed Change to the Technical SpecificStion o E

N Related to Inservice Inspection of Pressure Containing Welds in Vessel Penetrations

Dear Sir:

Enclosed for filing are three (3) signed originals and nineteen (19) copies of a document enticled, " Application for Amendment to Operating License", together with forty (40) copies of Attachment I and II thereto, comprising a statment of the proposed change to the Technical Specifications and the associated Safety Evaluation.

This application seeks tc amend Appendix A of the Operating Licens&.

The proposed change will correct a typographical error in Item 1.6 of Table 4.6-1 on page 159 of the Technice.1 Specifications.

The sub column "5 years" under the column ' Extent of Examination, % Inte.'<als" has the value 8, which is incorrect.

The correct entrf i; '0" (zero), as specified by Section XI of the 1970 ASME Code.

In accordance with Section XI of the 1970 edition of the ASME code, the visual exam required by Category E-2 shall i

i

_be done at the time of the system hydrostat c test requ red by l

Section IS-520.

Section IS-520 requires the hydrostatic test to be performed at or near the end of the inspection interval, which is 10 years.

The typographical error in the present Technical l

j Specifications referred to above would require a major hydro-static test every 5 years which would subject the plant to need-lessly high pressures.

8103020 370 o

7

. The Authority has classified this application for amendment to the operating license as Class II, consisting as it does of correction of a typographical error.

Enclosed is a check in the amount of $1,200 as the filing fee per 10CFR 170.22, which - the Authority pays under protest pending a final determination of the legality of the fee schedule.

Very truly yours, Gx. Mi J.

P.

Bayne Senior Vice President Nuclear Generation i

.