ML19341B838

From kanterella
Jump to navigation Jump to search
Mod 2,providing Funding for CY81 Effort & Modifying Some Monitoring Requirements,To Environ Monitoring Program W/State of Sc
ML19341B838
Person / Time
Issue date: 01/26/1981
From: Morton K
NRC OFFICE OF ADMINISTRATION (ADM), SOUTH CAROLINA, STATE OF
To:
Shared Package
ML19341B836 List:
References
CON-FIN-B-5112, CON-NRC-05-80-273, CON-NRC-5-80-273 NUDOCS 8102270906
Download: ML19341B838 (2)


Text

.

WAh0Ath IQWM 30. JULY $904 PAoI I dme. At srme.rs AD->N St Av.O~

AMENDMENT OF SOLICITA1 ON/ MODIFICATION OF COr! TRACT II j

d teOC StG 141 Cfs) 1 16101
8. AmtNDetNTimODIPiCAfsON NO
2. (ff tCTrk! Daft 3 3[Qu4[; mf,gg;,ga3g,EQVESI NO 4 PRO 4LCf NO f lf ef ph..shle, 2

1/1/81 S.155610 tv Cfil>E 6 Acurc5r ago av (/f.,A,,,4,. es.,e s j

( of >g l

U. S. fiuclear Regulatory Commission Division of Contracts Washington, DC 20555 1 CON 1dACtCR Lejl>l l l

F Alllli ) Lill)t l t

Naw! AND ADDif$$

,,,gggggg9 g, SCLICtf AfeCN NO I

State of South Carolina l

Department of Health and Environmental o^rfo (5-6/ 4 9;

,3,,,,,,,,,,,

Contro1 Cjj"'

Bureau of Radiological Health 5UiEOCE<c~En ~OfiRC-05-80-27.' _

2600 Bull Street L

Columbia, SC 29201 d

9/9/80 oAtD

,3,,,,,,,,,

9 f t il SLOCA APFut5 ONLT TO AmtND*ENTS Of 50uciTAf10Nb Ol'.-

~.1-.

- ~~.

-in.

'*-.-4

'o.0 0..~...........~......~...<-.-.u....~i--,

i.>.... 4

......~#,.,l.2,.........~~...l...........-,,w.m.,.....,..,.,...

FAILURE OF YOba ACKNowitDGimENT TO Bf tEClivtD AT TMt IS$U.NG O PICE P#iot TO THE NQue AND

= h.ch..el.h... 4.e-e

.he

&.e.e..

4.

aeae 6...

oA, C,iio A,,isuir,N.in CnO,. O,,Ou. C.,...

.....~~......~,...............u...'.

o,

im

..- u.

........~.

~.. '.v..

1D. ACCOUNilNG AND APr.OF' IAT.ON D ATA (8/ reg.sred) 31X0200.301 B&R fi0. 30-19-04-03 FIri fi0. B5112

$36,000.00 ti. TMis SLOCK APPU!S ONLY 10 #00i7tCAfsONS OF C 1NTRACY$tOfDtt$

i.> 0 2 c'. o *.....a.. -.- '.

1,.C~,....-~-~.,..

m o 7,..

,... o 4......

.s.

............ (c...... +.....

.........,. a i2 m g 1,... s

, A...-.

.~.

~....

,,,., 41 U. S. C. 252 )(10) w4..... ~.......

....a i t

12. DEscaiFfsON OF AmfNDMENTt wCOlFICAYlON I.

Article V - Consideration and Payment, Paragraph A., Consideration, the following change is made:

Subparagraph 3. is deleted in its entirety and the following new subparagraph 3. is substituted in lieu thereof:

"The amount obligated by the Coinmission in this Modification tio. 2 is $36,000.00. The total amount obligated under this Cooperative Agreement since its inception is $64,200.00."

II.

A new Attachment 5, Radiological Monitoring Program - Westinghouse fiuclear Fuel Division, is hereby added to and made a part of this Cooperative Agreement.

........i.....~..~~......e..........-..,

C"

'I

] TO 5 CONTRACTOS/CFFt#OR 15 BEQuit! YO SIGN ft.i$ DOCUwF i AND #fTV,N COF'IS TO f$$UeNG OFFICE TM S u

f Jts OF Am 1

(T to NAet OF CONThacTOe rOFf ttos 17.

N e,

,, e ov.

W (Svi w.e.8 p se.

g.p

(

15 g

,.e.* Cea

c. a, O.T ce.)

IS Pela.t AND fiTLt OF StGNet f Type.. pre.t1

16. DATE siGNto
18. NAmt Of CONT 8 AC9NG C FICf 8 f f.pe.c pratl 19 OAft SIGNED Kellogg V. Morton M

gl()2 mW n-ioi o u s ce<nman.isaism Radiological Monitoring-Program -

Westinghouse Nuclear Fuel Division Columbia, S.C.

Program Schedule Type of Sample Type or Analysis Freaucacy of Collec.tjon

' AIRBORNE PARTICULATES Gross alpha following each Weekly or monthly I sample from location of high filter change.

depending upon licensee's calculated ground level concentration program i sample from Control location at S.C. Department of Ilealth DIRECT EXPOSURE (TLD)

Gamma dose Quarterly by S.C. Department of licalth SURFACE WATER Total Uraniumi Quarterly

1. sample from immediate discharg area, spl h with licensee 1 sample - upstream control GROUND WATER Gross alpha Quarterly 1 sample from one onsite well, split with licensee l

FISil Total Uranium Annually 1 sample, split with licensee, from vicinity of discharge point VEGETATION' Total Uraniuml Seasonal 2 samples, split with licensee, of principal food products grown near point having highest X/Q l

SOIL Total Uranium Annually 1 sample split with licensee l

SEDIMENT Total Uranium Annually 1 sample split with licensee ISamples sent to RESL for analysis