ML19341B789

From kanterella
Jump to navigation Jump to search
Mod 2,adding TLD Monitoring Around Facilities & Increasing Amount of Contract to Environ Monitoring Program W/ Commonwealth of Pa
ML19341B789
Person / Time
Site: Peach Bottom, Beaver Valley  
Issue date: 01/07/1981
From: Gerusky T, Morton K
NRC OFFICE OF ADMINISTRATION (ADM), PENNSYLVANIA, COMMONWEALTH OF
To:
Shared Package
ML19341B785 List:
References
CON-FIN-B-5111, CON-NRC-05-80-272, CON-NRC-5-80-272 NUDOCS 8102270590
Download: ML19341B789 (4)


Text

.

..a c.

' AMENDMENT OF SOLICITATIONH.'.ODIFICATION OF CONTR ACT 3

i

.,w.A.c a m m.

.ni 5...Ci 5.c.o... s +..*, o~ i C,i iut

.ec..i c. i... m Au (N;= TNT, =,3C inc.f CN NO 2 If f f;Tive D Af t 3 e thi$11(/N / Fuh @ aS{ && Wv[ h? O I' D JLCl M ?fr

.s / 7 m

.e f

,o

.O:

2 4/1/A0

(,,ric l 51a w i,ty.a.,ae. u,.4 si com 5 <55uiD,

U. S. fluclear Regulatory Comiss ion Division of Contracts nr pn;ss Washinotnn.~

8-7 CONTs.CTOs (Opf l j

/ AC/LH F ( ODL l AwlNDMENT OF NAME AND ADC8155 SOilCIT AfiON NO l

Comonwealth of Pennsylvania

'5" S

  • 9 >

D m Department of Environmental Resources

.Ceinc.nO~ O.

5

,',., ",'- ll',,. B u re a u 6f Radiation Protection U co""'c"

' " "O _RRC-1 -E0-272 5"

..s m P. O. Box 2063 c.sa, Harrisburg, PA 17120

_J 4' 4/80 as->>>>

c A>tD L

, tw5 STOCK.P.L.E5 ONLY TO.uf NCantNis Of 50s,C#7 AT.ONS r.'.

'.+.<

.'o O

...-a.

..'.-*a O r..-. ~~s. w i

.. -.aa..

e.

~ > >-

ca......,.o...:u......,,.......,s..........<.w....,........s.

,..m e,

..v..

.e,s.....a...,

i...,,..m....,..$.

a.

m i,........i........ r..7 Agust of YOUR ACKNOwtf DGewENT TO SE in i, e.....

...l.

e..,e'e.e e

m e sei.c.e.n......me.....,

6...u..,..

.....i..a

w. a.

.. e.

~,6. ~.,..:....-

r Dart SrioniD - Av etsuo i~ isaCno~ 0, v0Vi Cute.

..........,-......6......<...

6....,...

... i.......

i..

10 ACCOVNTtNG AND APPROPRiAllON D ATA (4/ rt</a.sred) 31X0200.300 B&R fio. 30-19-04-03 FIri fio. 85111

$,1,500.00 APPLits ONLY 10 mODJICADONS of CONTRACTS /ORDf RS

11. TNIS SsOCK m

ri... C s.... O....

.o r.. C, v.a i 2. ~.. =,

.w.. ~.-6. a..~,.o,. -

m 0 t... ~ - a..

..o,

...a.,a,...t.o

.......... ~,..r

..v

.m....,..

...........i...

6i..i2.

41 U.S C. 252 (c1(10) m 0 n... $........I.r..

.... a -.....,,.,s

.r....5...~....,-,..,.....o.a>2.

4 2. CISCRiFiiON Of.uf ND wtNir mODiF # CATION The purpose of this modification is to provide for the addition of TLD monitoring around the Beaver Valley and Peach Bottom fluclear Power Stations under this Coopera-tive Agreement effective April 1, 1980.

Accordingly, the following changes are made:

Article V

_ Consideration and Payment, Paragraph A., Consideration, the I.

following changes are made:

A.

Subparagraph 1. is deleted in its entirety and the following new

(

subparagraph 1. is substituted in lieu thereof:

I i

"1.

The Commission will provide funds, subject to the availability of appropriation, to the State in the amount of $101,300.00 during the three (3) year period of performance.

The rate of payment to the State will be as follows:

t.-.....a....o...-....................w.e....,.....~.-..--,s.a.u....-.m COPits 70155UING OFFG h CONia.CTOarOFFERoa 15 BEculetD YO SIGN TMr5 DOCUutNT AND afTueN I 3.

TO 5t TM 5 Cuut iT. DUN:7 O $7 ATE 5 OF AmitifA 72!a d r

. 6 4,5 n.

C-.......

l.. NMaf OF CONTR ACYCR / C L

w'?f taOSh4 n..,.-....,

.., 0, _..C,,_, e.,,,,...,,..m D.,,. m D.,, m~m

,5 y,. D 11,. O,,m., r.,...,,..,,

-W ' m o99 V. f4orton

/,, 3 N-

m s i n <- 41 e, rg n, v h /2./ k C c r' O i b iT W/w.

" ~ " - " ' " * " " * " " " " * - " ' - ' "

~

8102270 9 9 3osoi

Modifica.on No. 2 to Contract tio. NRC-05-80-272 Page 2 f 3 CY 1980 - $7,200.00 per site, per year / environmental media program CY 1980 - $ 750.00 per site, per year /TLD program CY 1981 - $7,900.00 per site, per year / environmental

.nedia program CY 1981 - $1,100.00 per site, per year /TLD program CY 1982 - $8,700.00 per site, per year / environmental media program CY 1982 - $1,200.00 per site, per year /TLD program" B.

Subparagraph 3., as modified, is deleted in its entirety and the following.

new subparagraph 3. is substituted in lieu thereof:

"The arcunt obligated by the Commission in this Modification No. 2 is $1,500.00. The total amount obligated under this Cooperative Agreement since its inception is $30,300.00."

i II. Attachment A, Statement of Work, the following change is made:

Paragraph III, Procedures for Implementing and Conducting the Programs, is deleted in its entirety and the following new paragraph III is substituted in lieu thereof:

"III.

PROCEDURES FOR IMPLEMENTIf4G AND CONDUCTING THE PROGRAMS-A.

The Commission's Office of Inspection and Enforcement (IE)

Technical Representative will provide Lechnical liaison, as necessary, between the State and the licensee, in all matters relating to the program conducted pursuant to the Cooperative Agreement.

Tiie liaison may be delegated to the NRC Region I Technical Representative for the particular NRC Licensee involved.

I l

B.

The State will make all necessary contacts and arrangements for collecting samples in the off-site environment, e.g.,

obtaining access to private property, assistance of State or local agencies, arranging with private firms for services, etc.

C.

The State will make all necessary contacts and arrangements with the licensee to split samples with the licensee, obtain i>'

duplicate samples and obtain licensee's data on the comparative samples.

l l

D.

The Commission will assist the State in selecting sampling j

. locations, arranging for laborotory support, as necessary, l

spliting samples periodically, assisting State in obtaining i

licensee's comparative data, and consulting with:the State i

on matters of mutual concern.

I

Modification No. 2 to Contract No. HRC-05-80-272 Page 3 of 3 i

l E.

The State will exchange TLDs at stations established jointly by the Commission and the State on a frequency of 92 + 7 days starting on January 1,1980.

The interval betweer exchanges shall not be smaller than 80 days nor larger. than 100 days.

During an exchange, the State will replace TLDs currently in the field with annealled ILDs supplied by NRC Region I office.

Intransit control TLD will be placed in lead cask on arrival at State's point of dispatch.

Exposed TLDs will be shipped back to NRC Region I as soon as possible by conveyance agreed upon by the Commission and State.

F.

The State will notify the NRC Office of Inspection and Enforcement Region 1 Office by telephone (215 337-5217, FTS 488-1217) and written confirmation as soon as practicable after it becones aware of any observed unusual condition, level of radiation, or concentrations of radioactive material measured in carrying out the programs at individual sites.

G.

The Commission will make the necessary inspections, investi-gations, and inquiries to ascertain the status of compliance by the licensees with license provisions, rules, orders, and regulations of the Commission and to determine the safety of license

  • operations; and will initiate enforcement or other regulatory action as appropriate.

Results of such inspections.

-investigations, or inquiries conducted in response to such notification shall'be provided to the State."

III. ' A new Attachment-1, Environmental Radiological Verification Monitoring Program Around Nuclear Power Plants, Page 2, is hereby added to and made a part of this Cooperative Agreement.

IV. The contract amount is hereby increased by $6,100.00 from $95,200.00 to $101,300.00 by reason of this Modification Ho! 2.

i e

i f

i m

e me

.-e es m

-w*

e va -

h6inuklCili I (Q,pi'd) Expor.ure Pathway Number of Samples Sampling and Type of Freipiency and/or Sample r.nd Location Collection Frequency of Analysis Fo sd Products Two samples split with licensee, At time of harvest.

Gan=a isotopic on cdtble of principal food products grown portion.

Radiciodine near point having the highest' analysis on green leafy X/Q or from any area which is vegetable.

irrigiited by water in which liquid plant wastes have been discharged or green leafy vegetables at a private garden or farm in the iinnediate area of the plant.

Sediment from Shoreline One sample split with licensee Annually.

Gamma isotopic analysis.

TLD-Direct a.

TLD badges in 16 sectors Quarterly Analyses to be perforcied Rad i a t. ion around plant site at two by Commission, distances from site boundary:

Beaver Valley

1) Site boundary out to 1 mile
2) Two (2) to 4 miles from Peach Bottom site boundary.

b.

population centers within 10 miles, c.

Maximum exposed residences within 3 miles.

d.

liigh public interest sites tithin 5 miles, Backgroundcontrolsite(3) e.

greater than 15 miles from plant