ML19341B690

From kanterella
Jump to navigation Jump to search
Authorizes Delivery to Carrier for Transport of Large Equipment Decontaminated Waste Fixed in Accordance W/Statements & Representations Per 801120,1215,810112 & 20 Ltrs,Subj to Certain Conditions
ML19341B690
Person / Time
Site: 07106400
Issue date: 01/26/1981
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Sabo A
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
References
NUDOCS 8102270023
Download: ML19341B690 (2)


Text

    • De 8(

4 UNITED STATES NUCLEAR REGULATORY COMMISSION n

3 WASHINGTON, D. C. 20656 e

S-

,o FCTC: RHO 71-6400 x

.. ~

Westinghouse Electric Corporation ATTN: Mr. A. T. Sabo P. O. Box 355 Pittsburgh, PA 15230 Gentlemen:

Pursuant to 10 CFR Part 71, you are authorized to deliver to a carrier for transport large equipment waste which has been decontaminated and fixed in accordance with statements and representations made in your letters dated November 20 and December 15, 1980 and January 12 and 20, 1981 subject to the conditions stated below:

1.

Model No.:

6400 2.

Package Identification No.: USA /6400/B()F 3.

Drawings: Packaging is constructed in accordance with Protective Packaging, Inc., Drawing Nos.: 32106-1, Sheet 1, Rev. F; and 32106, Sheet 2; and either (1) Westinghouse Electric Corporation Drawing No. 2020008, Sheet 1 and 2, Rev. 0; or (2) Babcock and Wilcox Company Drawing No.11-D-2130, Rev. O, as modified by Westinghouse Electric Corporation letter dated January 12,1981; or (3) Nuclear Packaging, Inc. Drawing No. EG-60-OlD, Sheets 1 and 2, Rev. O, as modified by Westinghouse Electric Corporation letter dated January 20, 1981.

4.

Contents: Large decontaminated equipment waste of such size as not to fit into a 55-gallon drum (with legs or her readily removable appendages removed). Not to exceed 5 grams plutonium within the package.

Equipment waste surfaces shall be decont$minated to a smearable level 5.

of no more than 150,000 dpm/100 cm2 prior to fixation or until successive decontamination cleaning operations do not reduce the smear-able contamination levels by more than ten percent. After fixation, l

equipment waste surfaces shall have a smearable level of contamination of no greater than 10,000 dpm/100 cm2 Outer surfaces shall have a smearable level of contamination of no greater than 20 dpm/100 cm2, Prior to fixing of Ontamination, large equipment waste shall be inspected to insure that:

(a) all sharp or protruding objec'.s have been removed or blunted, and (b) pipe caps, gasketed blind f'.anges, covers, etc., have been installed wherever possible.

Following such l

inspection, the inner surfaces shall be fixed with " strip" or " clear" coating. The inner surface (s) may alternatively be fixed with a l

polurethane foam.

810227000

(

2-JAN 2 61981 For the seven (7) glove boxes designated as Westinghouse I.D.

Nos. 2, 3, 4, 7, 8, 9, and 11 which were decontaminated and fixed prior to the December 3,1980, the following contamination criteria shall be met: smearable level prior to fixation shall not exceed 300,00g dpm/100 cm2 and after fixation shall not exceed 25,000 dpm/

100 cm. All other requirements of this condition shall apply.

6.

The large equipment waste shall be enclosed in a tight fitting box constructed of 1" thick plywood. The space between the equipment and the box shall be fitted with foam.

7.

The maximum weight of the contents including secondary packaging, dunnage, shoring and bracing shall not exceed 30,000 pounds.

8.

Sufficient dunnage, shoring and/or bracing shall be utilized to minimize secondary impact of the secondary packaging within the cavity under nonnal and accident conditions.

9.

Protrusions from secondary packaging such as lifting eyes, etc.,

shall be positioned such that they will not contact the cavity walls, or shoring shall be provided to prevent puncture of the cavity walls by the protrusions under the normal and accident conditions.

10. Contents shall be positioned in the cavity such that the center of gravity of the loaded package is substantially the same as the center of gravity of an empty package.
11. Package Model No. 6400 is exempt from the requirements of 10 CFR 571.42 only for the purpose of making these shipments.
12. This approval supersedes in its entirety, approval (MacDonald to DiPiazza) letter dated December 18, 1980.
13. Expiration date: December 31, 1981.

REFERENCES Westinghouse Electric Corporation application dated July 13, 1973.

Mechanics Research, Inc., Report C2378, " Engineering Evaluation of the Super Tiger Overpack Designed for the Shipment of Large Quantities of Hazardous Materials."

Supplement Dated: January 12 and 20,1981.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles t.

cDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety cc: Richard R. Rawl, DOT Dr. Donald M. Ross, DOE

.