Forwards Final Draft Technical Evaluation Rept, Equipment Environ Qualification.
ML19341B522
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 01/31/1981
From: Carfagno S
FRANKLIN INSTITUTE
To: Vaughn Thomas
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML19341B523 List:
References
NUDOCS 8102020455
Download: ML19341B522 (1)


Text

.- .

N A)dFranklin Ib Research Center A Division of The Franklin Institute January 31, 1981 United States Nuclear Regulatory Commission hashing ton, D.C. 20555 Attention: Mr. Vincent D. Thomas Task Manager 79-OlB Utility: Commonwealth Edison Company Re f ere nce :

Plant Name Quad Cities huclear Power Station Unit 2 Docket No.: 50-265 ,

NRC TAC No.: 42479 EGsG Icaho, Inc.

Subcontract No.: K-7615 FRC Project No. : C5417 FRC Task No.: 13 Project: IE Bulletin 79-OlB Task Review Group Electrical Equipment Envircraental Qualification (EEQ)

Subject:

Final Draf t Technical Evaluation Report - Formal Issue Equipment Environmental Qualification

Dear Mr. Thomas:

Enclosed please find the non-proprietary version of the Final Draf t

~

Technical Evaluation Report on the referenced subject.

Very truly yours, S. P. Carfagno Project Manager SPC/CJC/cm Enclosure cc 2. Rosztoczy - Letter only P. DiBenedetto - 5 Reports W. Booth - Letter only- ((

'8102020455

.p

The Benjamin Franklin Parkway, Philadelphia. Pa.19103 . (215) 448 1000 TWX 710 6701889 l