ML19341A924

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-07, BWR Jet Pump Assembly Failure. No Abnormal Wear,Stress or Failed Welds Discovered During Visual Exams of Unit 2 Assemblies by Remote Underwater Television Cameras.Insp of Unit 1 Scheduled
ML19341A924
Person / Time
Site: Hatch  
Issue date: 01/13/1981
From: Widner W
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-80-07, IEB-80-7, NUDOCS 8101290376
Download: ML19341A924 (1)


Text

~

bG

\\

L b

  1. # "* 'd ""

January 13, 1981 m.,c

,e lo 0.,

United States Nuclear Regulatory Co p//

Office of Inspection and Enforceme %

REF:

RII-JP0 Region II - Suite 3100 t

50-321, 50-366 I

d@/

I&E Bulletin 101 Marietta Street, NW Atlanta, Georgia 30303 8/p

,C 80-07 g

b ATTENTION:

Mr. James P. O'Reilly 4"

% d' P

' '# /.49 g njN GENTLEMEN:

Inscection of Plant Hatch Unit 2 jet pump astemblies has been comoleted as required per I&E Bulletin 80-07, "BWR Jet Pump Assembly Failure."

Visual examinations by remote underwater television cameras of the Unit 2 jet pump structures, hold-downs, hold-down beam assemblies, and wedge and restrainer assemblies revealed no abnomal wear, stress, or failed welds.

Ultrasonic examinations utilizing General Electric pro-cedure TP-508.0642 (Rev. A) were also conducted on the jet pump hold-down beams at the midlength ligament areas bounding the beam bolt. It was determined that no cracking existed at those locations.

Visual and ultrasonic inspections of Hatch Unit 1 jet pump com-ponents are scheduled for examination during the Winter 1981 refueling outage scheduled to begin in February.

If you have any questions in this regard, please contact my office.

Sincerely yours, b

-f

./ / W. A. Widner JAE/mt xc:

M. Manry R. F. Rogers, III Sworn to and subscribed befoce me this 13th day of January, 1981 Notary Pubitc. Georgia. State at Large

t.. ~/ ~ '_i [

My Comm:ssion Empires Sept. 20.1983 Notary Public pg 1%O3%