Application for Revision of Certificate of Compliance 9111 to Permit Use of Improved Const Matls & Strengthened Outer Shell
ML19341A575
Person / Time
Site: 07109111
Issue date: 12/17/1980
From: Hansen L
NUCLEAR PACKAGING, INC.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML19341A576 List:
References
18123, NUDOCS 8101270143
Download: ML19341A575 (2)


Text

.

/]e 2/- 7m NUCLEAR PACKAGING, INC.

A 315 SO. 28TH STREET TACOMA. WASHINGTON 98409 * (206) 572 7775 83&1243 December 17, 1980 Charles E.

MacDonald, Chief i

Transportation Certification Branch e

Division of Fuel Cycle & Material Safety Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. MacDonald:

We respectfully request revision of Certificate of Compliance No. 9111, Model CN6-80A, to permit use of inproved materials of construction and a strengthened outer shell.

The requested change to materials of construction would perntit use of ASTM A-516, Grade 70 material in all instances where ASTM A-36 is presently specified.

ASTM A-516, Grade 70 possesses slightly improved strength properties over A-36 (5% greater yield stress and 20% greater ultimate stress) and clearly superior brittle fracture resistance properties, possessing a nil-ductility transition temperature some 40 -

500 below that of A-36.

The second requested change increases outer shell thickness from 1 inch to 1-1/8 inch.

Of note, this strengthened outer shell has essentially no impact upon the existing Safety Analysis Report but was altered to provide added puncture resistance should the package be subsequently submitted for evaluation as a Type B package.

Enclosed is our check number 5360 for $150.00 to cover the minor amendment fee for Category llE Packages under 10 CFR 170.31.

Eight (8) copies of the amended pages, plus instruc-tions for their corporation into the original application, are enclosed.

We trust this information is acceptable and suffic-ient to permit issuance of the revised certificate in the shortest possible time.

Sincerely yours, NUCLEAR P,ACKAGIN INC.

ff; '

,rh e v i any ansen LJH/ pro

Enclosures:

Check Number 5360 (8) copies CN6-80 SAR, Revision 3 C

8101270/*13 18123

j

~

INSTRUCTIONS FOR INCORPORATING REVISION 3 AMENDMENTS TO MODEL CN6-80 SHIELDED CASK APPLICATION, DATED DECEMBER 17, 1980 Insert new title page Remove old title page Insert new page 0-2 Remove old page 0-2 Insert new page 1-1 Remove old page 1-1 Insert new page 1-2 Remove old page 1-2 Insert new page 1-19 Remove old page 1-19 1

i

(

--