INTERIM REPORT 5
Accession No.
Contract Program or Project
Title:
Thermal Hydraulic LMFBR Safety Experiments Subject of this Document:
July Monthly Highlight Letter G
i k 9 f' Type of Document:
Monthly Highlight Letter g
9-
~d y
Author ( s):
Theodore Ginsberg and other?
JAN1Gl981"i-( UAWN I2 sxuPJstice Date of Document:
July 1980 f
- co to s
Responsible NRC Individual and NRC Office or Division:
Dr. Melvin Silberberg Division of Reactor Safety Research U.S. Nuclear Regulatory Commission Washington, D.C.
20555 This document was prepared primarily for preliminary or internal use.
It has not received full review and approval. Since there may be substantive changes, this document should not be considered final.
Brookhaven National Laboratory
- Upton, New York 11973 Associated Universities, Inc.
for the U.S. Department of Energy Prepared for
?
U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Under Interagency Agreement DE-AC02-76CH00016 FIN No. A-3024 a,
,c
+
Imv n.c "u
r. a.
ti101230M7 (CE ash i m' O i
o...
o Monthly Highlights for July, 1980*
1 Thermal Hydraulic LMFBR Safety Experiments Nesia Abuaf Experimental Modeling Group Department of Nuclear Energy Brookhaven National Laboratory Upton, New York 11973
- Work carried out under the auspices of the United States Nuclear Regulatory Commission.
1Li 4,,.
J e
l 1.
Thermal llydraulic LMFBR Safety Experiments 1.1_llydrodynamic Characteristics of Two-Phase Dispersed Systems (T. Ginsberg, J. Klages, Y. Sanborn, G. Zimmer; J. Chen, Lehigh Univ.)
Analysis of the data from the preliminary hydrodynamic dispersion tests was initiated.
Computer sof tware modifications were implemented in order to carry out the analysis.
1.2 HCDA Bubble Energetics (T. Ginsberg; J. Moszynski, Univ. of Delaware)
A final draf t of the report " Liquid Entrainment by an Expanding Gas or Vapor Bubble - A Review of Experiments and Models" was prepared. Typing of the report is near completion.
1.4 Fuel Relocation SL. dies (G.A. Greene)
Preparation of a final report, subsequent to transmittal of & draft to NRC on 7-1-80, continued.
1.5 Heat Transfer in Internally Heated Boiling Pools (G.A. Greene and S.M.
Reilly, MIT)
Experiments were performed to measure the temperature and pressure profiles in volume-boiling pools. Flow regimes investigated were bubbly, transition, and churn-turbulent.
The data is presently being analyzed to determine void pro-files, saturation profiles, and boiling inception.
1.6 Transition Phase Technology Assessment (G.A. Greene and T. Ginsberg)
Preparation of a final report, subsequent to receipt of critical reviews from DOE and LASL, continued.
Distribution Thermal Hydraulic LMFBR Development Program BNL RSP Division Heads BNL RSP Group Leaders BNL RSE Personnel P. Abramson, ANL D. Basdekas, NRC J. Boudreau, LASL I. Catton, University of California J. C. Chen, Lehigh University R. T. Curtis, NRC W. Gammill, NRC (2)
D. T. Eggen, Northwestern University H. H. Hummel, ANL (2)
W. Y. Kato, BNL M. S. Kazimi, MIT H. J. Kouts, BNL R. T. Lahey, Rensselaer Polytechnic J. T. Larkins, NRC A. Reynolds, University of Virginia M. Silberberg, NRC M. Stevenson, LASL T. G. Theofanus, Purdue University J. C. Walker, Sandia Laboratory R. W. Wright, NRC U.S. NRC Division of Technical Information and Control l
.. _